Data Format
(3)
Automatic alternate block allocation
Automatic alternate block allocation at read operation
If the ARRE flag in the MODE SELECT parameter permits the automatic alternate block allocation,
the IDD automatically executes the alternate block allocation and data duplication on the defective
data block detected during the READ or READ EXTENDED command. This allocation method is
the same as with the REASSIGN BLOCKS command (alternate sector treatment).
Automatic alternate block allocation at write operation
If AWRE flag in the MODE SELECT parameter permits the automatic alternate block allocation, the
IDD executes two kinds of automatic alternate processing during WRITE command processing as
described below:
Type 1 (Reassignment of Uncorrectable Read Error)
1) Commands to be applied
-
WRITE
-
WRITE EXTEND
-
WRITE at executing WRITE AND VERIFY
2) Application requirements
When any of the above commands is issued to LBA registered in the uncorrectable error log of
the READ command (LBA log of uncorrectable error while the READ command is executed),
the AWRE processing is applied.
3) AWRE processing
The following processings are performed when the LBA matches the one in the uncorrectable
error log:
a)
Primary media check
- Creates an uncorrectable error pattern (invalid LBA pattern) in the position of the error
LBA, repeats the primary media check up to three times. If the error still occurs after the
check repeated three times, it is judged to be defective. Then, it performs the alternate
processing.
b)
Alternate processing
- Alternate media check
Writes the data that causes an unrecoverable error into the alternate block, and performs
the media check.
(If the alternate block is a defective sector, the block is registered to the G list, another
alternate block is allocated.)
c)
SA and defect map update processing (on alternate side)
When an error occurs in the alternate processing, this WRITE command terminates with error.
When the alternate processing normally terminates, the WRITE command is executed.
Depending on the alternate processing result, one of the following sense codes is returned:
Alternate processing is succeeded: 01-OC-01
Fatal error (SA write retry out):
3-14
03-OC-02
C141-E198