Haier AB09CS1ERA Service Manual page 20

Commercial air conditioning
Hide thumbs Also See for AB09CS1ERA:
Table of Contents

Advertisement

Item
Function
Capacity
Sensible heat ratio
Dehumidifying capacity
Power Supply
Type × Number
Speed(H-M-L)
Fan
Fan motor output power
Air-flow(H-M-L)
Static pressure
Type / Diameter
Heat exchanger
Total Area
Temp. scope
External
Dimension
Package
Drainage pipe (material , I.D./O.D.)
Control type
(Remote /wired)
Noise level
(H-M-L)
Weight
(Net / Shipping)
Type
Refrigerant
Liquid
Pipe
Gas
Connecting Method
Norminal condition: indoor temperature (cooling): 27℃DB/19℃WB, indoor temperature (heating): 20℃DB
Outdoor temperature(cooling): 35℃DB/24℃WB, outdoor temperature(heating): 7℃DB/6℃WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound
intensity meter. It is a sound pressure noise level.
Model
kW
10‐³×m³/h
r/min
kW
m³/h
Pa
mm
(L×W×H)
mm×mm×mm
(L×W×H)
mm×mm×mm
mm
dB(A)
kg / kg
mm
mm
-20-
cooling
6.8(2.0---7.6)
0.72
1PH,220-230VAC,50HZ
1250±40/1130±40/1000±50/850±50
1200/1050/850(white terminal 0 Pa)
inner grooved pipe/φ7
AD24LS1ERA
heating
7.1(3.0---8.3)
/
2.2
centrifugal*2
0.05
25
0.51
2-7
1090*500*220
1174*549*294
20/24
wired, YR-E14
49/45/41/37
25.2/28.4
R410A
9.52
15.88
flared

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents