Haier AB09CS1ERA Service Manual page 17

Commercial air conditioning
Hide thumbs Also See for AB09CS1ERA:
Table of Contents

Advertisement

Item
Function
Capacity
Sensible heat ratio
Dehumidifying capacity
Power Supply
Fan
Static pressure
Heat exchanger
Dimension
Drainage pipe (material , I.D./O.D.)
Control type
(Remote /wired)
Noise level
(H-M-L)
Weight
(Net / Shipping)
Refrigerant
Pipe
Connecting Method
Norminal condition: indoor temperature (cooling): 27℃DB/19℃WB, indoor temperature (heating): 20℃DB
Outdoor temperature(cooling): 35℃DB/24℃WB, outdoor temperature(heating): 7℃DB/6℃WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated
sound intensity meter. It is a sound pressure noise level.
Type × Number
Speed(H-M-L)
Fan motor output power
Air-flow(H-M-L)
Type / Diameter
Total Area
Temp. scope
External
(L×W×H)
Package (L×W×H)
Type
Liquid
Gas
Model
kW
5.0(1.8---6.0)
10‐³×m³/h
r/min
kW
m³/h
Pa
mm
mm×mm×mm
mm×mm×mm
mm
dB(A)
kg / kg
mm
mm
-17-
AD18LS1ERA
cooling
5.5(2.0---6.2)
0.73
2.1
1PH,220-230V 50-60HZ
centrifugal fan X 2
700±30 / 540±30 / 400±30
50
850/780/600
25
inner grooved pipe/φ7
0.34
2-7
1090×500×220
1174×549×294
20/24
wired, YR-E14
41/35/32
23/26.5
R410A
Φ6.35
Φ12.7
FLARED
heating
/