View Menu; Diagnostic Indicators - Dell PowerVault NX3300 Owner's Manual

Owner's manual
Hide thumbs Also See for PowerVault NX3300:
Table of Contents

Advertisement

View Menu

NOTE: When you select an option in the View menu, you must confirm the option before proceeding to the next
action.
Option
Description
iDRAC IP
Displays the IPv4 or IPv6 addresses for the iDRAC7. Addresses include DNS (Primary and Secondary),
Gateway, IP, and Subnet (IPv6 does not have Subnet).
MAC
Displays the MAC addresses for iDRAC, iSCSI, or Network devices.
Name
Displays the name of the Host, Model, or User String for the system
Number
Displays the Asset tag or the Service tag for the system.
Power
Displays the power output of the system in BTU/hr or Watts. The display format can be configured in the
Set home submenu of the Setup menu.
Temperature Displays the temperature of the system in Celsius or Fahrenheit. The display format can be configured in
the Set home submenu of the Setup menu.

Diagnostic Indicators

The diagnostic indicators on the system front panel display error status during system startup.
NOTE: The diagnostic indicators are not present if the system is equipped with an LCD display.
The following section describes system conditions and possible corrective actions associated with these indicators:
Electrical indicator
Condition
The indicator blinks amber if the system
experiences an electrical error (for
example, voltage out of range, or a failed
power supply or voltage regulator).
Temperature indicator
Condition
The indicator blinks amber if the
system experiences a thermal error
(for example, a temperature out of
range or fan failure).
12
Corrective Action
See the System Event Log or system messages for the specific
issue. If it is due to a problem with the power supply, check the
LED on the power supply. Re-seat the power supply by removing
and reinstalling it. If the problem persists, see
Corrective Action
Ensure that none of the following conditions exist:
A cooling fan is removed or has failed.
System cover, cooling shroud, EMI filler panel, memory-
module blank, or back-filler bracket is removed.
Ambient temperature is too high.
External airflow is obstructed.
See
Getting Help.
Getting Help.