Sharp EL-509WM Operation Manual
Sharp EL-509WM Operation Manual

Sharp EL-509WM Operation Manual

Advertisement

SCIENTIFIC CALCULATOR
OPERATION MANUAL
INTRODUCTION
Thank you for purchasing the SHARP Scientific Calculator Model EL-509WM/
509WS.
About the calculation examples (including some formulas and tables),
refer to the reverse side of this English manual. Refer to the number on
the right of each title on the manual for use.
After reading this manual, store it in a convenient location for future
reference.
Operational Notes
• Do not carry the calculator around in your back pocket, as it may break
when you sit down. The display is made of glass and is particularly fragile.
• Keep the calculator away from extreme heat such as on a car dashboard
or near a heater, and avoid exposing it to excessively humid or dusty
environments.
• Since this product is not waterproof, do not use it or store it where
fluids, for example water, can splash onto it. Raindrops, water spray,
juice, coffee, steam, perspiration, etc. will also cause malfunction.
• Clean with a soft, dry cloth. Do not use solvents or a wet cloth.
• Do not drop it or apply excessive force.
• Never dispose of batteries in a fire.
• Keep batteries out of the reach of children.
• This product, including accessories, may change due to upgrading
without prior notice.
• SHARP strongly recommends that separate permanent written
records be kept of all important data. Data may be lost or altered in
virtually any electronic memory product under certain circumstances.
Therefore, SHARP assumes no responsibility for data lost or
otherwise rendered unusable whether as a result of improper use,
repairs, defects, battery replacement, use after the specified battery
life has expired, or any other cause.
• SHARP will not be liable nor responsible for any incidental or
consequential economic or property damage caused by misuse and/
or malfunctions of this product and its peripherals, unless such
liability is acknowledged by law.
♦ Press the RESET switch (on the back), with the tip of a ball-point pen or
similar object, only in the following cases. Do not use an object with a
breakable or sharp tip. Note that pressing the RESET switch erases all
data stored in memory.
• When using for the first time
• After replacing the batteries
• To clear all memory contents
• When an abnormal condition occurs and all keys are inoperative.
If service should be required on this calculator, use only a SHARP servicing
dealer, SHARP approved service facility, or SHARP repair service where
available.
Hard Case
DISPLAY
Equation→
Display
Mantissa
• During actual use, not all symbols are displayed at the same time.
• Certain inactive symbols may appear visible when viewed from a far off angle.
• Only the symbols required for the usage under instruction are shown in
the display and calculation examples of this manual.
: Appears when the entire equation cannot be displayed. Press
/
</> to see the remaining (hidden) section.
: Indicates that data can be visible above/below the screen.
These indications may appear when menu, multi-line playback,
and statistics data are displayed. Press [/] to scroll
up/down the view.
: Appears when @ is pressed, indicating that the functions
2ndF
shown in orange are enabled.
ENGLISH
EL-509WM
EL-509WS
MODEL
PRINTED IN CHINA
04KGK (TINSE0780EH01)
NOTICE
←Symbol
Exponent
: Indicates that h has been pressed and the hyperbolic
HYP
functions are enabled. If @H are pressed, the symbols
"2ndF HYP" appear, indicating that inverse hyperbolic functions
are enabled.
ALPHA: Indicates that K (STAT VAR), O or R has been
pressed, and entry (recall) of memory contents and recall of
statistics can be performed.
FIX/SCI/ENG: Indicates the notation used to display a value and changes
by SET UP menu.
DEG/RAD/GRAD: Indicates angular units and changes each time G
is pressed.
: Appears when statistics mode is selected.
STAT
M
: Indicates that a numerical value is stored in the independent
memory.
BEFORE USING THE CALCULATOR
Key Notation Used in this Manual
In this manual, key operations are described as follows:
: @e
To specify e
x
To specify ln : I
To specify F : Kü
Functions that are printed in orange above the key require @ to be
pressed first before the key. When you specify the memory, press K
first. Numbers for input value are not shown as keys, but as ordinary
numbers.
Power On and Off
Press ª to turn the calculator on, and @F to turn it off.
Clearing the Entry and Memories
Clearing methods are described in the table as follows:
Clearing
Entry
operation
(Display)
ª
@c
@∏00*
6
@∏10*
7
RESET switch
× : Retain
: Clear
*
1
Independent memory M.
*
2
Temporary memory A-F, X and Y.
3
*
Last answer memory.
4
*
Statistical data (entered data).
¯ x , sx, σ x, n, Σ x, Σ x
, ¯ y , sy, σ y, Σ y, Σ y
*
5
2
*
6
All variables are cleared. See 'About the Memory clear key' for details.
*
7
This key combination functions the same as the RESET switch. See
'About the Memory clear key' for details.
[About the Memory clear key]
Press @∏ to display the menu.
• To clear all variables (M, A-F, X, Y, ANS, STAT VAR), press 00
or 0®.
• To RESET the calculator, press 10 or 1®.
The RESET operation will erase all data stored in memory, and restore
the calculator's default setting.
Entering and Correcting the Equation
[Cursor keys]
• Press < or > to move the cursor. You can also return to the
equation after getting an answer by pressing > (<). See the next
section for using the [ and ] keys.
• In the SET UP menu and other locations, use the < or > key to
move the flashing cursor, then press ® (= key). If you need to
scroll up/down the view, use the [ or ] key.
[Insert mode and Overwrite mode in the Equation display]
• This calculator has two editing modes: insert mode (default), and overwrite
mode. Pressing @' switches between the two modes. A
triangular cursor indicates that an entry will be inserted at the cursor,
while the rectangular cursor indicates to overwrite preexisting data as
you make entries.
• To insert a number in the insert mode, move the cursor to the place
immediately after where you wish to insert, then make a desired entry. In
the overwrite mode, data under the cursor will be overwritten by the
number you enter.
• This mode setting will be retained until the next RESET operation is
executed.
[Deletion key]
• To delete a number/function, move the cursor to the number/function you
wish to delete, then press d. If the cursor is located at the right end of
an equation, the d key will function as a back space key.
1
2
M*
A-F, X,Y*
STAT*
3
ANS*
STAT VAR*
×
×
×
×
, Σ xy, r, a, b, c.
2
MEM RESET
0
1
4
5

Advertisement

Table of Contents
loading

Summary of Contents for Sharp EL-509WM

  • Page 1 • When an abnormal condition occurs and all keys are inoperative. or 0®. If service should be required on this calculator, use only a SHARP servicing • To RESET the calculator, press 10 or 1®. dealer, SHARP approved service facility, or SHARP repair service where The RESET operation will erase all data stored in memory, and restore available.
  • Page 2: Scientific Calculations

    Multi-line Playback function Determination of the Angular Unit This calculator is equipped with a function to recall previous equations in In this calculator, the following three angular units (degrees, radians, and the normal mode. Equations also include calculation ending instructions grads) can be specified.
  • Page 3: Statistical Calculations

    Fraction Calculations Single-variable statistical calculation This calculator performs arithmetic operations and memory calculations Statistics of Q and value of the normal probability function using fractions, and conversion between a decimal number and a fraction. Linear regression calculation • If the number of digits to be displayed is greater than 10, the number is Statistics of Q and W and, in addition, estimate of y for a given x converted to and displayed as a decimal number.
  • Page 4: Normal Probability Calculations

    Notes on erasure of memory contents When the battery is replaced, the memory contents are erased. Erasure can also occur if the calculator is defective or when it is repaired. Make a SHARP CORPORATION note of all important memory contents in case accidental erasure occurs.
  • Page 5: Calculation Examples

    ENGLISH • • • • ) – = 12 ™ 3 ™ 4 @•= 6.447419591 EL-509WM 8÷= 512. EL-509WS √ 49 – √ 81 = ⁄ 49 - 4 @$ 81 = CALCULATION EXAMPLES √27 = @# 27 = 4 @!=...
  • Page 6 ª 3 \ 1 \ 2 + ª 12 o 39 o 18.05 12°39’18.05” 3– + – = [a–] → [10] 4 \ 3 = 12.65501389 →[a.xxx] 4.833333333 123 ° 40’40.8” 123.678 @_ 123.678 →[d/c] → [60] @¡ 2 \ 3 3 o 30 o 45 + 6 o 3h30m45s + 10 =...
  • Page 7 k&~£pnzw^ ¢PZWvrab© x = Σx n Σx – nx xy≠ƒ«»√ σx = Σx = x Σx + ··· + x – nx DATA sx = Σx + ··· + x n – 1 95 k Σy Σy 80 k – ny σy = 75 &...
  • Page 8 • • • • 1000000000 ≤ x ≤ 1111111111 Function Dynamic range 0 ≤ x ≤ 111111111 2222222223 ≤ x ≤ 4444444444 Fungsi Julat dinamik 0 ≤ x ≤ 2222222221 H‡m s” Gißi hÂn Ò∂ng 4000000000 ≤ x ≤ 7777777777 0 ≤...

This manual is also suitable for:

El-509ws

Table of Contents