Wiring Diagrams - Dean Portable Filters MF90 Series Installation & Operation Manual

Mf90 series portable filters "u" & "au" configurations
Hide thumbs Also See for Portable Filters MF90 Series:
Table of Contents

Advertisement

6.3 Wiring Diagrams

OFF/ON HEATER SWITCH
PUMP REVERSING
SWITCH
BLK
CB
7 AMP
SWITCH HOUSING
T5
T8
T4
MOTOR
TERMINAL BOX
BLK
PUMP
CB
SWITCH
P1
P2
T3
T5
T2
T4
T8
MF90 Filter Wiring (AU)
TIMER
(OPTIONAL)
SWITCH
OPTIONAL
2 AMP
FUSE
RED
BLK 1
BLK 4
BLK 8
BLK 5
BLK 5
BLK 8
BLK 4
BLK 1
T1
WHT
MF90 Filter Wiring (U)
TIMER
7 AMP
SWITCH
BLK
BLK
WHT
INDICATOR
LIGHT
BLK
GRN
WHT
RED
WHT
Junction
Box
6-6
OPTIONAL
OPTIONAL
Suction Sump
Heater
One Way Valve
Heater
POWER CORD
AWG 16-3 SJT
BLK
GRN
WHT

Hide quick links: