Control Panel - Indesit ID60G1 Operating Instructions Manual

Free standing gas cooker
Table of Contents

Advertisement

Installation
INSTALLATION AND OPERATIONAL CHECKS
GB
After installation, check for gas soundness. The
supply pressure can be checked at the front left
hotplate burner injector.
Fit the hotplate burner bodies and caps, pan
supports and shelf shield(s).
Referring to the instructions for use where
necessary,
1. Check that the hotplate burners ignite and cross-
light to all ports. Check for a steady flame on the
low setting.
2. Check that the grill burner ignites and cross-lights
to all ports and that the flames remain when the
control is released 3 seconds later, Check for a
steady flame on the low setting.

Control Panel

* Only available in certain models
8
Top oven
Timer knob*
knob
Main oven
knob
Top oven
Electronic
knob
Timer *
Main oven
knob
3. Check that with the main oven set to mark 9, the
burner ignites and that tha flames remain when the
control is released 3 seconds later. Leave the oven
full on with the door closed for 10 minutes, and
check that when the control is turned to mark 1 that
the flame reduces.
4. Check that with the top oven set to mark 8, the
burner ignites and that the flames remain when the
control is released 3 seconds later. Leave the oven
full on with the door closed for 10 minutes, and
check that when the control is turned to mark 1 that
the flame reduces.
5. Check the operation of the timer and oven light.
Instruct the user on operation of the cooker.
On those models adjusted for use with LPG, it is
normal for the oven and grill burners to burn with
yellow tips.
Hob knobs
Hob knobs

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Id60g2

Table of Contents