7. Flow Chart of Troubleshooting

7-1. Power On
' Power On ' does not work
Check the Battery Voltage
is more than 3.3V
U401 pin57(PS_HOLD)
= 2.6V ?
Check the Clock at
XTAL401= 3 2.768KHZ
C413(VREG_MSMC) =
1.375V ?
C415(VREG_MSME) = 1.8V ?
C421(VREG_MSMP) = 2.6V ?
C423(VREG_MSMA) = 2.6V ?
C433(VREG_TCXO) = 2.85V ?
Check for the clock at
C407= 19.2MHz
Check the initial operation
END
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
SAMSUNG Proprietary-Contents may change without notice
This Document can not be used with out Samsung's authorization
No
Change the Battery
No
Check the PMIC related to PS_HOLD
No
Resolder XTAL401
No
Check the PMIC
No
Check the PMIC
No
Check the clock generation circuit
(related to OSC201)