17
Installation Instructions
Suitable isolation devices include line protecting cut outs, fuses (screw type fus
es are to be removed from the holder), earth leakage trips and contactors.
Connect down draught extractor to an air tight vent hose or vent pipe with a
120 mm diameter and at least 1 m long.
Important: Do not connect down draught extractor to the voltage supply until
an adequate air outlet has been provided.
Do not connect vent hose or vent pipe to an air shaft, flue or similar which is al
ready in use.
If several Frontline appliances are installed, install down draught extractor be
tween the appliances.
Distance from flammable materials: at least 150 mm
Important: Official regulations must be followed when drawing off exhaust air.
Important: Do not conduct exhaust air to a chimney which is used by appliances
operated with gas or other combustible fuels.