Electrical Connection - AEG 6000 K Operating Instructions Manual

Ceramic glass hob
Table of Contents

Advertisement

Electrical Connection

• The mains connection terminals are on the underside of the
appliance, behind a cover. The hob is to be connected in accordance
with the connection diagram as a function of the mains supply pre-
sent...
• The earth conductor is connected to the
must be longer than the current carrying wires. If necessary, the brid-
ges on the terminal block must be changed as appropriate.
• The cable connections must be made in accordance with regula-
tions and the terminal screws fully tightened.
• The connecting cable is then to be secured using the strain relief
clamp.
• Following connection to the mains supply, all cooking zones are to be
1
switched on, at the maximum setting, one after the other for approx.
30 seconds to check that they function correctly.
Connection Diagram 230 V
1
2
3
4
L1
N
230 V~
1
2
3
4
L1
L2
N
230 V~
230 V~
Installation Instructions
~
5
PE
5
PE
terminal, the earth wire
230 V~
2 N~
79