General Information - MULTIQUIP QP305SLT Operation And Parts Manual

High pressure centrifugal pump (honda gx340k1pkt2/gx340u1pkt2 gasoline engine)
Hide thumbs Also See for QP305SLT:
Table of Contents

Advertisement

appLICaTIoN
The QP305SLT/QPT305SLT centrifugal pump is a high
pressure pump designed to be used for dewatering
applications. The suction port on the QP305SLT/
QPT305SLT uses a 3-inch diameter opening. There are
three discharge ports on the pump, 2 are 1-inch in diameter
and the third is 1.5-inches in diameter. This pump can
discharge water at a rate of approximately 145 gallons/
minute (gpm) or 550 liters/minute (lpm).
Centrifugal or self-priming pumps are designed to purge
air from the suction line and create a partial vacuum in the
pump body. The reduced atmospheric pressure inside the
pump allows water to flow through the suction line and into
the pump body. The centrifugal force created by the rotating
impeller pressurizes the water and expels it from the pump.
Power Plant
This centrifugal pump is powered by an 9.5 HP, air-cooled
4-stroke, single-cylinder HONDA GX340 gasoline engine
that incorporates a low "Oil Alert Feature".
oil alert Feature
In the event of low oil or no oil, the HONDA GX340 engine
has a built-in oil alarm engine shutdown feature. If the oil
level is low the engine will automatically shut down.
Standard Centrifugal Pump
Standard centrifugal pumps provide an economical
choice for general purpose dewatering. These types of
pumps should only be used in clear water applications
(agricultural, industrial, residential) as they have a limited
soild handling capability of only 10% by volume.
Suction Lift
This pump is intended to be used for dewatering applications
and is capable of suction lifts up to 25 feet at sea level. For
optimal suction lift performance keep the suction hose or
line as short as possible. In general always place the pump
as close to the water as possible.
Pump Support
The pump should always be placed on solid stationary
ground in a level position.
page 12 —Qp305SLT/QpT305SLT CeNTRIFUgaL pUMp • opeRaTIoN aNd paRTS MaNUaL — Rev. #1 (10/11/10)

General inFOrMatiOn

NeveR place the pump on soft soil. The suction hose or
pipe connection should always be checked for tightness
and leaks. A small suction leak in the hose or fittings could
prevent the pump from priming.
Elevation
Higher elevations will effect the performance of the pump.
Due to less atmospheric pressure at higher altitudes,
pumps do NoT have the priming ability that they have at
sea level. This is due to the "thinner air" or lack of oxygen
at higher altitudes.
A general rule of thumb is that for every 1,000 feet of
elevation above sea level a pump will lose one foot of
priming ability.
For example, in Flagstaff, Arizona where the elevation is
approximately 7,000 feet, the pump would have a suction
lift of only 18 feet rather than the 25 feet at sea level.
Table 3 shows suction lift at various elevations.
Table 3. Suction Lift at various elevations
Altitude
Feet
Suction Lift in Feet (Meters)
(Meters)
Sea Level
10.0 (3.048) 15.0 (4.572) 20.0 (6.096) 25.0 (7.620)
2,000 (610)
8.80 (2.680) 13.2 (4.023) 17.6 (5.364) 22.0 (6.705)
4,000 (1,219)
7.80 (2.377) 11.7 (3.566) 15.6 (4.754) 19.5 (5.943)
6,000 (1,829)
6.90 (2.103) 10.4 (3.169) 13.8 (4.206) 17.3 (5.273)
8,000 (2,438)
6.20 (1.889) 9.30 (2.834) 12.4 (3.779) 15.5 (4.724)
10,000 (3,048) 5.70 (1.737) 8.60 (2.621) 11.4 (3.474) 14.3 (4.358)
Table 4 shows percentage drops in performance as
elevation increases.
Table 4. performance Loss at various elevations
Altitude
Discharge Flow
Feet (Meters)
Sea Level
2,000 (610)
4,000 (1,219)
6,000 (1,829)
8,000 (2,438)
10,000 (3,048)
Discharge Head
100%
100%
97%
95%
95%
91%
93%
87%
91%
83%
88%
78%