Now, Connect The Antenna - NETGEAR ANT24D18 Installation Manual

18 dbi patch panel directional antenna
Hide thumbs Also See for ANT24D18:
Table of Contents

Advertisement

Wall Mount with Adjustable Bracket
2 plastic
screws
tube
screw
tube
screw
screw nut
bracket A
washer
Wall Mount with Fixed Bracket
8
bracket B
2-screw
washer
screw nut

Now, Connect the Antenna

The instructions below cover outdoor and indoor installations.
Connecting the Antenna for an Outdoor Installation
1.
Turn off your wireless unit.
2. Connect the provided 2-meter cable to the antenna and to the arrestor as shown here. You
can connect the cable to either of the two RF ports on the lightning arrestor.
Wireless unit's
DC block
Wireless unit
ETHERNET
5-12V DC
RESET
NETGEAR cable
ACC-10314-01, 02, 03, 04, 05
Ethernet
(Sold separately)
(CAT 5) cable
3. Connect the grounding cable (not included) from the lightning arrestor to the ground of
the building.
Grounding cable: The grounding cable must be equivalent or better than: AWG 10, UL
1015, Stranded, 600 V, 105°C, green or green/yellow insulation, 2 clip of 5.5 mm inner
diameter cramped at both ends, cable no longer than 5 meters.
Warning: the lightning arrestor and appropriate ground cable must be used for outdoor
installation. NETGEAR does not assume any responsibility in case of hazard resulting of
non-compliance with these instructions.
4. Screw the N/SMA Reverse Adapter on the lightning arrestor (clockwise) on the second RF
port. Connect a NETGEAR cable model ACC-10314-01, 02, 03, 04 or 05 (sold
separately) to the adapter.
5. Locate the primary detachable antenna on the wireless access point. Remove the antenna
and connect the other end of the NETGEAR cable ACC-10314-01, 02, 03, 04 or 05 to
this port.
18 dBi Patch Panel
Directional Antenna
ANT24D18
N/SMA adapter
Lightning
arrestor
2m cable
(provided)
Ground cable
Building
(Not provided)
grounding
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents