SPECIFICATION DATA
MODEL
In-
Door
136
•
181
•
264
•
331
•
399
•
512
•
627
•
726
•
825
•
926
962
•
1083
1125
•
1178
1223
•
1287
1337
•
1413
1467
•
1570
1630
•
1758
1826
•
Rated inputs are suitable for up to 2000 feet elevation. For elevations above 2000 feet, reduce input 4% for each
1000 feet above sea level. These heaters are tested and certified to ANSI Standard Z 21.10.3
MBH Natural Gas
Sanimaster
STYLE
(Indoor)
Out-
Input
Output
Door
136.0
•
181.0
•
264.0
•
•
334.0
399.0
•
511.5
•
627.0
•
726.0
•
825.0
•
•
961.7
•
1124.7
•
1222.5 1002.4
•
1336.6 1096.0
•
1467.0 1203.0
•
1630.0 1336.6
•
1825.6 1497.0
Typhoon
(Outdoor)
Input
Output
112.0
136.0
112.0
148.0
181.0
148.0
216.0
264.0
216.0
274.0
334.0
274.0
327.0
399.0
327.0
419.4
511.5
419.4
514.0
627.0
514.0
595.0
726.0
595.0
676.5
825.0
676.5
926.0
759.0
788.6
1083.0
888.0
922.0
1178.0
966.0
1287.0 1055.0
1413.0 1158.5
1570.0 1287.0
1758.0 1441.5
4
ELECTRICAL RATINGS
Model
Size
With Pump
136-264
3.4 amps @ 120V(1/8 hp pump)
331-399
3.6 amps @ 120V(1/6 hp pump)
512-1826 7.9 amps @ 120V (1/2 hp
pump)
MBTUH PROPANE GAS†
Model
Size
Multiplier
136-399
Same as natural gas
512-825
.94
926-1826
.92
Indoor
.955 Outdoor (Input)
.92
Outdoor (Output)
† Multiplier x Nat. MBTUH =
Pro. MBTUH