The function selection is done through configuration register1
Function
Phase A
Phase B
Reset input
Comparison value 1 MW12 MW13
Comparison value 2 MW14 MW15
Count value
Soft-gate
Interrupt enable 1
Count preset 1
Interrupt enable 2
Count preset 2
Hardware condition:
Phase A and phase B (IP 1 and IP 2)
1X Mode
ON/OFF pulse width: 100 micro sec. or more (max. 5 kHz)
2X Mode
ON/OFF pulse width: 100 micro sec. or more (max. 5 kHz)
4X Mode
ON/OFF pulse width: 100 micro sec. or more (max. 5 kHz)
Reset input (IP3)
ON/OFF duration: 2 ms or more
Interrupt assignment:
Comparison value 1 — I/O interrupt program #1
Comparison value 2 — I/O interrupt program #2
Register/device
IP 1 (X000)
IP 2 (X001)
IP 3 (X002)
MW16 MW17
M320
M322
M324
M323
M325
Remarks
Data range: 0 to 4294967295
Operation is enabled when ON
Interrupt 1 is enabled when ON
Used to preset the count value
Interrupt 2 is enabled when ON
Used to preset the count value
Page 93