Clearance Dimensions (Proximity To Cabinets); Clearance Dimensions (Wood/Composite Overlay) - Viking RDECU266 Installation Manual

Built-in electric cooktop
Table of Contents

Advertisement

Clearance Dimensions
Proximity to Side Cabinet Installation
Minimum Clearances from Adjacent
Combustible Construction
• The cooktop may be installed directly to
existing base cabinets.
• Above countertop 36" (91.4 cm) minimum
• The cooktop CANNOT be installed
• Side 6" (15.2 cm)
directly adjacent to sidewalls, tall cabinets,
• Rear 0" (0.0 cm)
tall appliances, or other side vertical
• Within 6" side clearance. Wall cabinets no
surfaces above 36" (91.4 cm) high. There
must be a minimum of 6" (15.2 cm) side
• Must be minimum 18" (45.7 cm) above
clearance from the cooktop to such
combustible surfaces above the
• Wall cabinets directly above the product
36" (91.4 cm) counter height.
• Within the 6" (15.2 cm) side clearance to
combustible vertical surfaces above
36" (91.4 cm), the maximum wall cabinet
depth must be 13" (33.0 cm) and wall
cabinets within this 6" (15.2 cm) side
clearance must be 18" (45.7 cm) above
the 36" (91.4 cm) high countertop.
• Wall cabinet above the cooktop
must be a minimum of 36"
(91.4 cm) above the countertop
for a full width of the cooktop.
The minimum height requirement
does NOT apply if a rangehood is
installed over the cooking surface.
" m
1 8
. 7
( 4 5
i n .
" m
)
c m
3 6
. 4
9 1
(
Dimensions shown are for use
with combustible surfaces unless
otherwise stated.
*Note: 36" minimum unless using a hood.
**Note: Only applies to combustible surfaces.
***Note: Refer to installation of holddown brackets on page 13 for
minimum clearances under counter
8
(Proximity to Cabinets)
deeper than 13" (33.0 cm)
countertop
must be minimum 36" (91.4 cm) above
the countertop
.
a x
" m
)
1 3
c m
. 0
3 3
(
i n .
" m
) *
i n .
3 6
c m
. 4
( 9 1
)
c m
Clearance Dimensions
The bottom of a standard hood should be
30" (76.2 cm) min. to 36" (91.4 cm) max.
above the countertop. This would typically
result in the bottom of the hood being
66" (167.6 cm) to 72" (182.9 cm) above the
floor. Refer to the rangehood installation
instructions for additional information. These
dimensions provide for safe and efficient
operation of the hood.
6 6
" m
( 1 6
i n .
7 . 6
c m
t o
7 2
" m
( 1 8
a x
2 . 9
c m
W o
o d
/ C o
m p
O v
o s i
e r l
t e
a y
6 6
"
" m
3 0
( 1 6
)
i n .
c m
3 0
7 . 6
. 2
" m
c m
( 7 6
( 7 6
i n .
7 2
t o
)
. 2
" m
c m
( 1 8
a x
t o
)
3 6
2 . 9
.
" m
6 "
c m
( 9 1
m )
a x
)
. 4
.
. 2 c
c m
( 1 5
)
Island Installation
9
(Wood/Composite Overlay)
W o
o d
/ C o
m p
O v
o s i
e r l
t e
a y
"
2 4
)
c m
. 0
( 6 1
)
3 0
" m
( 7 6
i n .
.
. 2
c m
)
t o
)
3 6
" m
( 9 1
a x
. 4
.
c m
)
Wall Installation

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rdecu2665bsbRdecu2566bsbRdecu256Rdecu2065bsbRdecu206D3 rdecu106 ... Show all

Table of Contents