Download Print this page

Whirlpool ECKMF-64 Installation Instructions page 4

Automatic ice maker

Advertisement

Connect Ice-Maker
To Water (Contd.)
1.
2.
3.
4.
5.
Find a %-inch to 1 -inch vertical COLD water pipe near
the refrigerator. (Horizontal pipe will work. ..but extra
precautions
must be taken.) (See * in Step 4.) Con-
nect to unsoftened water line if possible.
Measure from inlet on rear of refrigerator to water pipe.
Add 7 feet to allow for moving refrigerator for cleaning.
This is the length of X-inch O.D. copper tubing you
will need for the job (length from inlet tube to water
pipe PLUS 7 feet). Be sure both ends of copper tubing
are cut square.
Turn OFF main water supply. Turn ON nearest faucet
long enough to clear line of water.
Using a grounded
drill, drill a %-inch hole in the
vertical cold water pipe you have selected. Use of
self piercing
valve may lead to flow problems
in
the future.
Some water almost always remains in
pipes. If it enters the drill, it can cause lethal shock.
BE SURE YOUR DRILL IS GROUNDED.
Fasten a separate ground wire from drill to a good
ground that complies to local electrical codes. (If in
doubt,
consult
a licensed
electrician.)
UNLESS
PROPER GROUNDING
IS FOLLOWED, YOU ARE
NOT PROTECTED AGAINST SEVERE OR LETHAL
SHOCK.
l
If you must use a horizontal
pipe, take extra
precautions:
Drill on the top or side of the pipe, not bottom.
This helps keep water away from the drill. Also, it
keeps normal sediment from collecting in the valve.
Fasten shutoff valve to cold water pipe with pipe
clamp. Be sureinletend
is solidly in the X-inch drilled
hole in the water pipe and that washer is under the
pipe clamp. Tighten packing nut. Tighten the pipe
clamp screws carefully and evenly so washer makes
a watertight
connection.
Do not overtighten
or you
may crush copper tubing, especially
if soft copper
tubing is used. Now you are ready to connect the
copper tubing.
PIPE CLAMP,
,
/WASHER
SHUTOFF
VALVE
PACKING
NUT
OUTLET
Step 5 and 6
Slip compression
nut and compression
sleeve on
copper tubing as shown in diagram. Insert end of
tubing into outlet end squarely as far as it will go.
Screw compression
nut to outlet end with adjustable
wrench.
Do not over-tighten. Turn ON main water
supply and flush out tubing until water is clear. Turn
7.
8.
9.
10.
11.
12.
13.
OFF shutoff valve on the water pipe. You are now
ready to connect other end of %-inch copper tubing
to inlet tube or water valve on back of refrigerator.
Assemble compression
nuts on tubing as shown in
diagram. Insert ends of tubing into connector
and
tighten compression
nuts. Be sure ends of tubing are
squarely in connector as far as they will go. Do not
overtiahten.
'/I" TUBE TO
SHUTOFF VALVE
CONNECTOR
SLEEVE
NUT
UNION-
WATER VALVE TUBE
+t
Step 7
LJ
Turn shutoff valve ON. TIGHTEN
ANY CONNEC-
TIONS OR NUTS THAT LEAK.
REPLACE
LOWER BACK COVER PREVIOUSLY
REMOVED
IN STEP 12, PAGE 3.
Copper tubing may now be fastened to baseboard.
The Ice Maker has a built-in water strainer on the inlet
side of the water valve. Use a second water strainer
when local water conditions require periodic cleaning
or a well is your source of water. The strainer can be
installed in the %-inch water line.
Water pressure should not be below (15 PSI.)
or
above (125 P.S.I.). If problem occurs call your Utility
Company.
PLUG IN YOUR REFRIGERATOR.
When you have your first batch of ice you may throw
away extra parts.
IMPORTANT:
It may take up to 24 hours for your Ice Maker to begin
producing
ice crescents.
To enjoy your Ice Maker most PLEASE READ CARE-
FULLVTHE
ICE MAKER SECTION OFYOUR
USE AND
CARE GUIDE.

Advertisement

loading