7 Start-up
Display
Title display
screen
screen
C21
Total system
parameters
C22
Total system
parameters
C23
Floor drying
HC2 does not
appear if
"Zone" selected
in heating
circuit mode
HC2 in A2
(Hydraulic
drawing 4)
C24
Service
C25
Tools
C26
Software
versions
Table 7.2 Display screens in the level for the expert technician
(continuation)
18
adjustable
Remarks
operating values
(just display = A)
Mode Auto_OFF
Determines the heating
control outside the
programmed time
window
Frost protection
Delay time of the start of
delay time
the frost protection
function or the ECO
function.
Max. pump blocking
If the feed set target
time
temperature is achieved
for a longer period of
time, the heating is
switched off for the
prescribed pump
blocking time (dependent
upon the external
temperature)
Max. pre-heating
Before the start of the
time
first time window
Max. pre-switch off
Before the end of a time
time
window
AT through-heating
External temperature
from which continuous
through-heating takes
place
Excess temperature
Increases the set heating
circuit target value this
can, in certain
circumstances, improve
the control performance
of the mixer;
if, in A2, for heating
circuit mode HC2 "Zone"
is selected (hydraulic
drawing 4) the value 0
for excess temperature is
applicable
floor drying - day
See Section 7.3Function
floor drying
floor drying/feed
See Section 7.3Function
floor drying
target value (A)
Telephone number
Entry of the telephone
FHW
number for the service
requirement
Changing the code
number
Maintenance date
Day/Month/Year
adjustable
Outside
Matching of the external
temperature
sensor
correction
Correction room
Matching the room
actual value
temperature sensor
Display contrast
Software-Version
Display of version
VR 61 (A)
number
Unit
Min.
Max.
value
value
Hrs.
0
12
Mins.
Off, 5
60
Mins.
0
300
Mins.
0
120
°C
OFF,
+10
-25
R
0
15
Day
0
29
°C
0000
9999
R
-5
5
R
-3
3
0
15
Operating and installation manual for VR 61 mixer module
Step width
Preset
value
Frost
Frost
protection,
protection
ECO, set-back
1
4
1
15
10
0
10
0
1
Off
1
0
1
0
in accordance
with
temperature
profile
each 1
1000
1,0
0
0,5
0
1
6