Start-Up; Installation Assistant - Vaillant VR 61 Operating And Installation Manual

Supplement to the operating and installation instructions no. 0020044359 for mixer module
Hide thumbs Also See for VR 61:
Table of Contents

Advertisement

Note!
h
If a charging pump or circulation pump is
connected, the configuration is carried out
using the installation assistant of the controller
VRC 430 or VRC 430f.
1
2
Fig. 6.3 Fitting the feed sensor 1
Key
1
Feed sensor 1 (VR 10)
2 6 pole edge connector X8 for plug socket location in the control
cabinet of the heating equipment
After connecting the electrical installation:
Secure all the lines in the VR 61 with the included
cable brackets (see Fig. 5.2).
Insert the casing cover back of the VR 61 into the
hinges and hinge the casing cover
back up into position.
Screw the casing cover in
position in accordance with Fig. 5.1.
Operating and installation manual for VR 61 mixer module
Electrical installation 6
7

Start-up

The commissioning of the mixwe module VR 61 is carried
out in conjunction with the commissioning of the
controller VRC 430 or VRC 430f.
Proceed in accordance with the instructions in the
manual of the VRS 430 or VRC 430f controller.
7.1

Installation assistant

When commissioning for the first time, you will be
supported by the installation assistant.
With the installation assistant you can enter the most
important parameters of the heating system.
The following differences are produced by the
installation of the mixer module VR 61 in the heating
system with respect to the standard configuration as
described in the manual for the VRC 430 or VRC 430f:
– Display screen A2
Installation assistant
System configuration
Mixer mode HC1
Mixer mode HC2
Cylinder
Base display (G1)
> Select
Fig. 7.1
Installation assistant display screen A2
The configuration of the heating system is shown in
display screen A2.
In the heating circuit mode HC1 you can select between
burner circuit (BK) and inactive.
In the heating circuit mode HC2 you can select between
mixer circuit (MK), inactive and Zone.
Note!
h
If the heating system is structured in
accordance with hydraulic drawing 4, i.e. two
uncontrolled heating circuits, "Zone" must be
selected in heating circuit mode HC2.
In the case of the storage tank you can switch between
active and inactive.
Using the parameter basic display (G1) you can
determine whether the display screen G1 is not shown at
all (value "OFF") or whether the values from heating
circuit 1 or heating circuit 2 are dispalyed.
Start-up 7
A 2
BK
MK
active
HC1
13