Connection To The Main Supply - Vaillant ecoTEC SERIES Instructions For Installation And Servicing

Wall hung room sealed fan assisted condensing boiler
Hide thumbs Also See for ecoTEC SERIES:
Table of Contents

Advertisement

4 Boiler installation sequence

4.14.2 Connection to the main supply

Fig. 4.13 Opening the electronics box
• Remove the front case and lower the control panel.
• Unclip the bottom of the terminal box cover and hinge
back to reveal the connection plugs.
• Feed the power supply flex into the appliance and the
control panel through the cable clamps provided and
tighten.
26
Fig. 4.14 Wiring system
• Connect the flex to the L, N and earth plug to the
terminal block.
Green/yellow (earth) wire – boiler terminal Earth sign
Blue (neutral) wire
Brown (live) wire
Note
Do not connect any power voltage to the
connections 7-8-9 or BUS (+,-).
Note
Ensure that the wires are securely fixed in the
terminal block.
• Refit the terminal box cover by pushing into place
until it clips back into position.
• Raise the control panel.
Instructions for installation and servicing ecoTEC 839592_12
- + 7 8 9
L N
3 4 5
- + 7 8 9
L N
3 4 5
– boiler terminal N
– boiler terminal L