Maximum Cable Distances - Bose ControlSpace CC-16 Safety Instructions & Install Manual

Zone controller
Table of Contents

Advertisement

Maximum cable distances

Wire Gauge/
Power Supply Voltage
24 AWG 18V
24 AWG 12V
24 AWG 9V
18 AWG 18V
18 AWG 12V
18 AWG 9V
Installing the mounting box
Install a dual-gang electrical box for each CC-16. Install the wall box so that it is flush or just
below the surface of the finished wall. The unit is designed to fit in North American, Japanese,
Australian and some European dual-gang electrical boxes. Mount the European and Australian
double-gang boxes horizontally and the North American and Japanese boxes vertically as
shown below.
Select a place that is convenient for the people who
will be controlling the system. We suggest mounting
the unit at eye-level for optimal LCD viewing angle.
CAUTION: Do not install the CC-16 in a box that has AC power (mains).
CAUTION: Do not place the power or network cables in the same conduit with the mains wire,
unless you are sure that special regulatory insulation requirements are met. Consult your local
electrical regulatory agency for further information.
Installation
1
2000 ft (610 m)
1852 ft (564 m)
1481 ft (451 m)
741 ft (226 m)
370 ft (113 m)
185 ft (56 m)
2000 ft (610 m)
2000 ft (610 m)
2000 ft (610 m)
2000 ft (610 m)
1515 ft (461 m)
758 ft (231 m)
8
Number of CC-16s
2
4
926 ft (282 m)
370 ft (113 m)
93 ft (28 m)
2000 ft (610 m) 1010 ft (308 m)
1515 ft (461 m) 404 ft (123 m)
379 ft (115 m)
15
247 ft (75 m)
99 ft (30 m)
25 ft (7 m)
101 ft (31 m)

Hide quick links:

Advertisement

Table of Contents
loading