PLUME DISPLACEMENT ACCESSORIES

Key Accessory
Plume Displacement - Black - 60/100mm diameter
A
Plume Displacement Kit (Black)
(includes terminal assembly, 1000mm extension,
outlet elbow and 2 support brackets)
B
Exhaust PDK Extension
(Black - inc. Brackets)
C
PDK Bend (Black)
D
PDK Bend (Black) (Pair)
E
Support Bracket (Black)
A
Telescopic Flue
Terminal
© Baxi Heating UK Ltd 2011
Size
Code No
Ø100
720622901
1000mm
720643301
93°
720648601
135°
720648701
Ø60
720623301
PDK
Terminal
Key Accessory
Plume Displacement - White - 60/100mm diameter
A
Plume Displacement Kit (White)
(includes terminal assembly, 1000mm extension,
outlet elbow and 2 support brackets)
B
Exhaust PDK Extension
(White - inc. Brackets)
C
Plume Bend (White)
D
Plume Bend (White) (Pair)
E
Support Bracket (White)
B

FITTING PLUME DISPLACEMENT KIT

The Plume Displacement Kit replaces the terminal assembly of the
standard telescopic flue kit (720598701, 720642701, 720599401 &
720870201 only).
The kit may be employed either at the time of fitting the boiler, or
retrospectively if the circumstances of the installation change such
that flue position no longer meets regulations, e.g. the building of an
extension adjacent to the flue terminal or other obstructions.
Remove the screws securing the standard terminal assembly and
withdraw it from the air duct. Discard the terminal and screws.
Take the PDK terminal assembly and insert it into the telescopic
flue. Secure using the new screws provided with the PDK.
New installations - fit the telescopic flue with the PDK terminal to
the boiler and make good the wall.
Cut the 1000mm extension to length if required, ensuring that the
end is square and free of burrs.
Determine the position of the support clamps and drill and plug the
wall. Fit the extension to the terminal and fix the clamps to the wall.
Tighten the clamps and fit the outlet elbow to the female end of
the extension. The outlet should be perpendicular to the wall (i.e.
90°) but may be angled to either side by no more than 45°.
Important Note: When fitting PDK retrospectively.
If screws and tape have been used to secure the flue system air
ducts and boiler elbow together originally, installation should be
straightforward. However, if any movement of the flue system
inside the dwelling is suspected, the integrity of flue should be
checked by performing a flue gas analysis at the boiler adaptor
air sampling point.
page 12
Size
Code No
Ø100
720627001
1000mm
720643401
93°
5121369
135°
5121370
Ø60
720627801
C
E
D