Baxi Solarflo Commissioning, Maintenance & Servicing Manual page 11

Solar thermal domestic hot water system
Hide thumbs Also See for Solarflo:

Advertisement

Info
Current collector temperature
/ Collector1
Minimum collector temperature
/ Collector1
Maximum collector temperature
/ Collector1
Current storage cylinder
temperature / storage1 at bottom
Minimum storage cylinder
temperature / storage1 at bottom
Maximum storage cylinder
temperature / storage1 at bottom
Current storage cylinder temp /
storage2 at bottom / collector 2
Minimum storage cylinder temp /
storage2 at bottom / collector 2
Maximum storage cylinder temp /
storage2 at bottom / collector 2
Current collector
temperature - return line
Current temperature
heating / cooling /
differential controller
heating source
Current temperature
frost protection sensor /
differential controller heating
target / universal measuring
point T6
Operating hours pump1
Yield storage1
Operating hours pump2
Yield storage2
Solarflo - Solar Thermal Domestic Hot Water System
Program
Maximum temperature
storage cylinder1
Storage cylinder1
Td max (Td on)
Storage cylinder1
Td min (Td off)
Maximum temperature of
storage cylinder2
Storage cylinder2
Td max (Td on)
Storage cylinder2
Td min (Td off)
Minimum
pump rotating speed in %
Start temperature
Heating / cooling
Hysteresis temperature
heating / cooling Td
Temperature differential
controller:
Maximum temperature of the
heating target Tmax
Temperature differential
controller:
Minimum temperature of the
heating source Tmin
Temperature differential
controller:
Hysteresis Tdmax
Temperature differential
controller:
Hysteresis Tdmin
Timeframe start 1,2,3 for the
independent controller, 4 for the
tube collector function
Timeframe stop 1,2,3 for the
independent controller, 4 for the
tube collector function
Set time
3.0
Commissioning of solar controller
3.1.4 Overview: Construction of menu structure
The overview shows the whole menu structure.
According to basic adjustment and system type some
menu points may not be displayed.
Manual operation
Pump1 off / on
Pump2 / Valve1
off / on
Heating / Cooling / Temperature
differential controller
off / on
Basic setting
Collector protection function
off / on
Collector protection
temperature
Re-cooling
off / on
Re-cooling
temperature
Tube collector
off / on
Yield estimation
off / on
Glycol type
Glycol percentage
Volume flow
Controlling time in
seconds
Storage cylinder priority
Frost protection
off / on
Frost protection sensor
assignment
Frost protection:
start temperature
Independent controller
assignment: Cooling, heating,
temperature differential
controller
Sensor assignment for the
independent controller
Select basic configuration
11