Trane IntelliPak CG-SVX02B-EN Installation & Operation Manual page 32

Air-cooled cold generator, "k" and later design sequence, with 3-dtm scroll compressors
Table of Contents

Advertisement

Table 4
Unit Electrical Data
Min.
Unit
Rated
Ckt.
6
1
Size
Voltage
Amp.
200/60/3
98
230/60/3
98
CGAF
460/60/3
44
20
575/60/3
33
380/50/3
44
415/50/3
44
200/60/3
124
230/60/3
124
CGAF
460/60/3
56
25
575/60/3
44
380/50/3
55
415/50/3
55
200/60/3
146
230/60/3
146
CGAF
460/60/3
65
30
575/60/3
51
380/50/3
65
415/50/3
65
200/60/3
187
230/60/3
186
CGAF
460/60/3
82
40
575/60/3
62
380/50/3
81
415/50/3
81
200/60/3
224
230/60/3
223
CGAF
460/60/3
98
50
575/60/3
77
380/50/3
97
415/50/3
97
200/60/3
270
230/60/3
269
CGAF
460/60/3
120
60
575/60/3
95
380/50/3
119
415/50/3
119
Notes:
1. Minimum Circuit Ampacity is 125% of the largest compressor RLA plus 100% of the other compressor
RLA plus the sum of the condenser fan FLA plus any other load rated at 1 Amp or more.
2. Maximum Fuse Size is 225% of the largest RLA plus 100% of the other compressor RLA plus the sum
of the condenser fan FLA plus any other load rated at 1 Amp or more.
3. Recommended Dual Element Fuse Size is 150% of the largest compressor RLA plus 100% of the
other compressor RLA plus the sum of the condenser fan FLA plus any other load rated at 1 Amp or more.
4. RLA is rated in accordance with UL Standard 465. Local codes may take precedence.
5. All units are across-the-line starting. Compressors will never start simultaneously.
6. (60 Hz units) One field provided 115/60/1, 15 amp power supply is required to operate the evaporator
heat tape.
(50 Hz units) One field provided 240/50/1, 5 amp power supply is required to operate the evaporator
heat tape.
Max.
Fuse
Compressor Motor (Each)
2,3
Size
Qty.
RLA
125
2
39.4
125
2
39.4
60
2
17.2
45
2
13.2
60
2
17.2
60
2
17.2
175
2
39.3/56.9
175
2
39.3/56.9
80
2
17.1/25.4
60
2
13.8/20.2
80
2
17.3/25.2
80
2
17.3/25.2
200
2
56.9
200
2
56.9
80
2
25.1
70
2
19.9
80
2
25.2
80
2
25.2
225
4
39.4
225
4
39.4
90
4
17.2
70
4
13.2
90
4
17.2
90
4
17.2
250
4
35.5/55.5
250
4
35.5/55.5
110
4
16.5/24.2
90
4
12.4/19.4
110
4
15.5/24.2
110
4
15.5/24.2
300
4
56.9
300
4
56.9
125
4
25.4
110
4
20.2
125
4
25.2
125
4
23.2
Installation
5
Cond. Fan Motors (Each)
4
LRA
Qty.
269
2
251
2
117
2
94
2
110
2
110
2
269/409
3
251/376
3
117/178
3
95/143
3
110/174
3
110/174
3
409
4
376
4
178
4
143
4
174
4
174
4
269
4
251
4
117
4
95
4
110
4
110
4
269/409
6
251/376
6
117/178
6
94/143
6
110/174
6
110/174
6
409
6
376
6
178
6
143
6
174
6
174
6
32
FLA
Kw
4.1
0.9
4.1
0.9
1.8
0.9
1.4
0.9
1.7
0.75
1.7
0.75
4.1
0.9
4.1
0.9
1.8
0.9
1.4
0.9
1.7
0.75
1.7
0.75
4.1
0.9
4.1
0.9
1.8
0.9
1.4
0.9
1.7
0.75
1.7
0.75
4.1
0.9
4.1
0.9
1.8
0.9
1.4
0.9
1.7
0.75
1.7
0.75
4.1
0.9
4.1
0.9
1.8
0.9
1.4
0.9
1.7
0.75
1.7
0.75
4.1
0.9
4.1
0.9
1.8
0.9
1.4
0.9
1.7
0.75
1.7
0.75