Viking CTG-2 Technical Practice page 15

Advanced clock controlled tone / message generator and master clock

Advertisement

The CTG-2 has limited Touch Tone programming allowing you to call the unit remotely and program the following functions:
Turn unit ON or OFF, Select a Schedule or Calendar mode or Force a Time Sync.
Accessing the Programming Mode Remotely
Step 1. Call into the CTG-2 from a touch tone phone.
Step 2. The CTG-2 will automatically answer and provide 1 beep.
Step 3. Enter the 6-digit security code (factory set to 845464, see PC Programming section).
Step 4. A double beep will indicate that you have accessed the programming mode.
Touch Tone programming commands:
Turn unit ON ..............................
Turn unit OFF ............................
Hang up .....................................
Force a Time Sync .....................
Reset trigger inputs 1 - 4 ............
Select Schedule 1 – 14 ..............
Select Calendar Mode ...............
Confirmation beeps: Two beeps will be heard indicating a correct entry. Three beeps will be heard indicating an incorrect
entry (error) or 3 seconds has elapsed since the last partially entered touch tone command. If this happens, simply re-enter
the command slowly and deliberately. The CTG-2 has a 20 second inter digit Touch Tone time out. If you exceed 20 sec-
onds between Touch Tone entry the unit will output 3 beeps and hang up.
Force a Time Sync: After entering "#8" two beeps will be heard, the unit will drop the line and then initiate a "Forced Time
Sync" to the Atomic Clock (ACTS). The internal Modem in the unit will seize the phone line, speed dial ACTS and down
load the current time and date. This process will take approximately 30 seconds in which time the unit will display "Pro" on
the clock display. The default phone number to perform a sync is "9 (1 second pause) 13034944774". This is programmed
on the "Set Up Clock" screen. If the CTG-2 was unable to sync with ACTS the display will rotate between flashing the clock
time, "Snc" and "Err". The unit will then redial every 5 minutes until it has a successful sync or reaches a maximum call
attempt of 15. If the unit was unable to sync after 15 attempts, the display will continue to rotate between flashing the clock
time, "Snc" and "Err".
Reset Trigger Inputs 1-4: Tones / messages (wave files) started from trigger inputs 1-4 can be reset (stopped) remotely
from a touch tone phone. Simply access the programming mode (see steps 1-4 above) and enter "#9". A double beep
should be heard. Trigger inputs 1-4 will then be reset (stopped). The trigger input's contact closure will then require an
"open" before the next trigger (contact closure) can activate the tone / message (wave file).
#1
#0
#4
#8
#9
1 - 14 then enter #7
99 then enter #7
15