ELECTRICAL RATINGS

Rated electrical characteristics are within ±10 percent of the indicated values of Isc, Voc and within +10/-5 percent of Pmax under Standard Test
Conditions (irradiance of 100 mW/cm
this manual.
Maximum Power (Pmax)
Open-Circuit Voltage (Voc)
Short-Circuit Current (Isc)
Voltage at maximum power (Vpmax)
Current at maximum power (Ipmax)
Maximum System Voltage
Minimum Blocking diode
Series Fuse
Maximum Power (Pmax)
Open-Circuit Voltage (Voc)
Short-Circuit Current (Isc)
Voltage at maximum power (Vpmax)
Current at maximum power (Ipmax)
Maximum System Voltage
Minimum Blocking diode
Series Fuse
Maximum Power (Pmax)
Open-Circuit Voltage (Voc)
Short-Circuit Current (Isc)
Voltage at maximum power (Vpmax)
Current at maximum power (Ipmax)
Maximum System Voltage
Minimum Blocking diode
Series Fuse
Under normal conditions, a PV module may produce more current and/or voltage than reported at Standard Test Conditions. Accordingly, the values
of Isc and Voc marked on UL 1703 listed modules should be multiplied by a factor of 1.25 when determining component voltage ratings, conductor
ampacities, fuse sizes and size of controls connected to the module output. Refer to Sec. 690-8 of the National Electric Code for an additional
multiplying factor of 125 percent (80 percent de-rating) which may be applicable. Where Canadian UL listing applies, installation shall be in
accordance with CSA C22.1, Safety Standard for Electrical Installations, Canadian Electrical Code, Part 1.
C) ELECTRICAL INFORMATION
, AM 1.5 spectrum, and a cell temperature of 25˚C (77˚F)). The warranty conditions are specified elsewhere in
2
ND-U230C1
230.0 W
37.0 V
8.24 A
30.3 V
7.60 A
600 V
15 A
15 A
ND-224UC1
ND-220UC1
224.0 W
220.0 W
36.6 V
36.5 V
8.33 A
8.24 A
29.28 V
29.19 V
7.66 A
7.54 A
600 V
600 V
15 A
15 A
NT-175UC1
175.0 W
44.4 V
5.40 A
35.4 V
4.95 A
600 V
10 A
10 A
ND-U224C1
ND-U216C1
224.0 W
216.0 W
36.9 V
36.7 V
8.07 A
7.85 A
30.2 V
30.2 V
7.42 A
7.16 A
600 V
600 V
15 A
15 A
15 A
15 A
ND-216UC1
216.0 W
36.5 V
8.10 A
28.9 V
7.48 A
600 V
15 A
15 A
15 A
15 A
NT-170UC1
NE-170UC1
142.0 W
170.0 W
43.2 V
43.2 V
5.47 A
5.47 A
34.8 V
34.8 V
4.90 A
4.90 A
600 V
600 V
10 A
10 A
10 A
10 A
- 6 -
Ver. 2.0U Dec. 4, 2008
ND-208UC1
ND-200UC1
208.0 W
200.0 W
36.3 V
36.01 V
7.99 A
7.90 A
28.71 V
28.42 V
7.25 A
7.04 A
600 V
600 V
15 A
15 A
15 A
15 A
NE-165UC1
165.0 W
43.1 V
5.31 A
34.6 V
4.77 A
600 V
10 A
10 A