Electrical Ratings; Electrical Information - Sharp NU-Q240F2 Installation And User Manual

Photovoltaic modules
Table of Contents

Advertisement

ELECTRICAL RATINGS

Rated electrical characteristics are within ±10 percent of the indicated values of Isc, Voc and within +10/-5 percent of Pmax under Standard Test Conditions
(irradiance of 100 mW/cm2, AM 1.5 spectrum, and a cell temperature of 25˚C (77˚F)). The warranty conditions are specified elsewhere in this manual.
Maximum Power (Pmax)
Open-Circuit Voltage (Voc)
Short-Circuit Current (Isc)
Voltage at maximum power (Vpmax)
Current at maximum power (Ipmax)
Maximum System Voltage
Minimum Blocking diode
Series Fuse
Maximum Power (Pmax)
Open-Circuit Voltage (Voc)
Short-Circuit Current (Isc)
Voltage at maximum power (Vpmax)
Current at maximum power (Ipmax)
Maximum System Voltage
Minimum Blocking diode
Series Fuse
Maximum Power (Pmax)
Open-Circuit Voltage (Voc)
Short-Circuit Current (Isc)
Voltage at maximum power (Vpmax)
Current at maximum power (Ipmax)
Maximum System Voltage
Minimum Blocking diode
Series Fuse
Maximum Power (Pmax)
Open-Circuit Voltage (Voc)
Short-Circuit Current (Isc)
Voltage at maximum power (Vpmax)
Current at maximum power (Ipmax)
Maximum System Voltage
Minimum Blocking diode
Series Fuse
Under normal conditions, a PV module may produce more current and/or voltage than reported at Standard Test Conditions. Accordingly, the values of Isc
and Voc marked on UL 1703 listed modules should be multiplied by a factor of 1.25 when determining component voltage ratings, conductor ampacities,
fuse sizes and size of controls connected to the module output. Refer to Sec. 690-8 of the National Electrical Code for an additional multiplying factor of
125 percent (80 percent de-rating) which may be applicable. Where Canadian UL listing applies, installation shall be in accordance with CSA C22.1, Safety
Standard for Electrical Installations, Canadian Electrical Code, Part 1.
C) ELECTRICAL INFORMATION
NU-Q240F2
NU-Q235F2
240.0 W
37.4 V
8.65 A
30.1 V
7.98 A
600 V
15 A
15 A
ND-230QCJ
ND-224QCJ
230.0 W
36.9 V
8.45 A
29.3 V
7.85 A
600 V
15 A
15 A
ND-H245Q2
ND-H240Q2
ND-Q245Q2
ND-Q240Q2
245.0 W
37.6 V
8.63 A
30.4 V
8.06 A
600 V
15 A
15 A
ND-Q235C5
ND-Q230C5
235.0 W
37.1 V
8.50 A
30.3 V
7.76 A
600 V
15 A
15 A
- 6 -
NU-Q235F4
235.0 W
235.0 W
37.0 V
37.0 V
8.60 A
8.50 A
30.0 V
30.1 V
7.84 A
7.81 A
600 V
600 V
15 A
15 A
ND-216QCJ
224.0 W
216.0 W
36.6 V
36.5 V
8.33 A
8.10 A
29.28 V
28.9 V
7.66 A
7.48 A
600 V
600 V
15 A
15 A
ND-H235Q2
ND-Q235Q2
240.0 W
235.0 W
37.5 V
37.2 V
8.61 A
8.59 A
30.2 V
30.1 V
7.95 A
7.81 A
600 V
600 V
15 A
15 A
230.0 W
36.6 V
8.44 A
30.0 V
7.67 A
600 V
15 A
15 A
Ver. 6.0U _ May 31, 2011
NU-Q230F4
230.0 W
37.0 V
8.40 A
30.0 V
7.67 A
600 V
15 A
15 A
15 A
15 A
15 A
15 A
ND-H230Q2
ND-Q230Q2
230.0 W
37.1 V
8.48 A
30.0 V
7.67 A
600 V
15 A
15 A
15 A
15 A
Installation Manual for PV Modules

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nd-230qcjNu-q235f2Nu-q235f4Nd-224qcjNu-q230f4Nd-216qcj ... Show all

Table of Contents