7. Specifications
PARAMETERS
ELECTRICAL:
Normal input solar cell array voltage
Max input solar cell array voltage
Max charging current:
Charging start when Battery voltage not less than
Current Consumption when connected 15V Array
(Battery not present)
Current Consumption when connected 12V battery
(Array not present)
PWM Constant-voltage for Gel-cell battery
PWM Constant voltage for Lead-acid battery
Float mode voltage
METER DISPLAY:
LED Bar graph indicated range (Battery Voltage status)
LOW LED
FAIR LED
GOOD LED
LCD Meter Accuracy- DC Voltage
LCD Meter Accuracy- DC Current- at 5~30Amp
PROTECTION:
Over temperature protection starting at (Stop charging)
Over temperature protection reset at (Restart Charging)
MECHANICAL
Controller Dimension
Controller overall Height
Net weight
ENVIROMENTAL CHARACTERISTIC:
Operation temperature
Storage temperature
T e c h n I c a l
S p e c i f i c a t i o n s
UNITS
Volt
16.5~22
Volt
Amps
Volt
Milliamps
Milliamps
Volt
14.1 +/-0.3
Volt
14.5 +/-0.3
Volt
13.4 +/-0.3
Volt
<11.5 +/-0.3
Volt
11.5 to 12.5 +/-0.3
Volt
>12.5 +/-0.3
Volt
Amps
ºC
ºC
mm
180 (L) x 104(W)
mm
Approx. 45
g
Approx. 350
ºC
ºC
DATA
25
30
5.0 +/-0.3
25Max.
25Max.
1.25%
3%
>80
<65
-5 to 50
-10 to70