Amana PTC 073G Product Specifications

Amana PTC 073G Product Specifications

Ptac air conditioners and heat pumps 11.7 eer / 3.4 cop

Advertisement

Quick Links

P
s
roduCT
PeCifiCATions
Product Features
• Quiet operation: STC of 28
• Assembled in the USA for 30 years
• Increased dehumidification capacity
• 100% run-tested at our plant in
Fayetteville, TN, for leaks
• 7⅝" unit front depth: one of the shallowest
silhouettes in the industry today
• Removable condenser shroud allows easy
access to enable regular cleaning of coils
• Easy pull-out filters that are washable and easy to maintain
• Filter drier for sealed system refrigerant
• 7-Button touch pad provides complete control to guests
for in-room comfort while maintaining energy efficiency
• Condensate dispersion system removes condensate
from indoor cooling operation and evaporates it into
the atmosphere through the condenser
• Digismart™ front desk control &
energy management software
• Room freeze protection is activated when
the unit senses temperatures of 40°F or below
• Versatile style that blends into any room's color
scheme and decor
• Easy to service with on-board led diagnostics
• Digismart™ wireless remote thermostat is available
• Remote temperature sensing for guest climate control
• Extended heat pump heating down to as low
as 24°F outdoor ambient temperature
• Zero floor clearance allows unit to be installed
flush to a finished floor
• 30-second fan-off delay
• Compressor lock-in prevents compressor short-cycling
• Constant fan mode
• Hidden ventilation control
• High-pressure switch
First-Year Warranty: Parts & Labor
Second through Fifth Year: Parts & Labor on certain sealed system components
Second through Fifth Year: on certain functional parts only
* Complete warranty details available at w ww.amana-ptac.com.
SS-DPTAC
Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas.
PTAC A
11.7 EER / 3.4 COP
Control Board
www.amana-ptac.com
C
ir
ondiTioners
H
P
And
eAT
umPs
2/13
Supersedes 9/12

Advertisement

loading

Summary of Contents for Amana PTC 073G

  • Page 1 • Compressor lock-in prevents compressor short-cycling • Constant fan mode • Hidden ventilation control • High-pressure switch First-Year Warranty: Parts & Labor Second through Fifth Year: Parts & Labor on certain sealed system components Second through Fifth Year: on certain functional parts only * Complete warranty details available at w ww.amana-ptac.com. SS-DPTAC www.amana-ptac.com 2/13 Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas. Supersedes 9/12...
  • Page 2 PTC073E25CQRW Heater   S ize No   E lectric   H eat 3.5   k W   ( 230/208V) 1.5   k W 3.7   k W   ( 265V) 2.5   k W 5.0   k W www.amana-ptac.com SS-DPTAC...
  • Page 3 10.0 Unit without Electric Heater Min. Circuit Amps ² ⁴ ¹⁰ High CFM (Cool/Wet Coil) High CFM (Dry Coil) Ventilated Air, CFM (Fan Only)* Dehumidification (Pints/Hr.) Net Weight (lbs.) Ship Weight (lbs.) * Actual vent CFM performance will vary due to application and installation conditions. Notes ¹ All 265-volt models must use an Amana® brand sub-base (PTSB4**E) or an Amana® brand hard-wire kit PTPWHWK4 and disconnect switch PSHW04A. ² Minimum Circuit Ampacity (MCA) ratings conform to the National Electric Code; however, local codes should apply. ³ Minimum voltage on 230/208-volt models is 197 volts; maximum is 253 volts. Minimum voltage on 265-volt models is 239 volts; maximum is 292 volts. ⁴ Overcurrent protection for all units without electric heaters is 15 amps. Overcurrent protection on 265-volt models must be cartridge-style time-delay fuses (included and factory-installed on all Amana® brand 265-volt chassis). See heater performance ⁵ Heating capacity and efficiency based on unit operation without condensate pump; unit automatically switches to electric heat at approximately 24°F outdoor ambient. ⁶ Specify two-digit heater kW size to complete model number. ⁷ R-410A refrigerant used in all systems. ⁸ All units meet or exceed ASHRAE 90.1 standards. ⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards. ¹⁰ Refer to electric heat performance data for total MCA and recommended overcurrent protection. Amps and Watts notation refers to compressor only. SS-DPTAC www.amana-ptac.com...
  • Page 4 11.7 / 11.7 11.5 / 11.5 10.7 / 10.7 9.7 / 9.7 11.7 11.5 10.7 Unit without Electric Heater Min. Circuit Amps ² ⁴ ¹⁰ High CFM (Cool/Wet Coil) High CFM (Dry Coil) Ventilated Air, CFM (Fan Only)* Ventilated Air, CFM (Comp & Fan)* Dehumidification (Pints/Hr.) Net Weight (lbs.) Ship Weight (lbs.) * Actual vent CFM performance will vary due to application and installation conditions. Notes ¹ All 265-volt models must use an Amana® brand sub-base (PTSB4**E) or an Amana® brand hard-wire kit (PTPWHWK4). ² Minimum Circuit Ampacity (MCA) ratings conform to the National Electric Code; however, local codes should apply. Minimum voltage on 230/208-volt models is 197 volts; maximum is 253 volts. ³ Minimum voltage on 265-volt models is 239 volts; maximum is 292 volts. ⁴ Overcurrent protection for all units without electric heaters is 15 amps. Overcurrent protection on 265-volt models must be cartridge-style time-delay fuses (included and factory-installed on all Amana® brand 265-volt chassis). ⁵ Heating capacity and efficiency based on unit operation without condensate pump; unit automatically switches to electric heat at approximately 24°F outdoor ambient. ⁶ Specify two-digit heater kW size to complete model number. ⁷ R-410A refrigerant used in all systems. ⁸ All units meet or exceed ASHRAE 90.1 standards. ⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards. ¹⁰ Refer to electric heat performance data for total MCA and recommended overcurrent protection. Amps and Watts notation refers to compressor only. www.amana-ptac.com SS-DPTAC...
  • Page 5 265V 8,500 2,570 12.2 7-20 P 265V 12,600 3,770 14.2 17.9 7-20 P 265V 17,100 5,070 19.2 23.9 7-30 P Notes ¹ All 265-volt models must use an Amana® brand sub-base (PTSB4**E) or an Amana® brand hard-wire kit (PTPWHWK4). ² Minimum branch circuit ampacity ratings conform to the National Electric Code; however, local codes should apply. ³ Minimum voltage on 230/208-volt models is 197 volts; maximum is 253 volts. Minimum voltage on 265-volt models is 239 volts; maximum is 292 volts. ⁴ Overcurrent protection for all units without electric heaters is 15 amps. Overcurrent protection on 265-volt models must be cartridge-style time-delay fuses (included and factory-installed on all Amana® brand 265-volt chassis). ⁵ Heating capacity and efficiency based on unit operation without condensate pump; unit automatically switches to electric heat at approximately 24°F outdoor ambient. ⁶ Total watts for 15,000 BTU/h models; subtract 20 watts for PT07/09/12 ⁷ Specify two-digit heater kW size to complete model number. ⁸ R-410A refrigerant used in all systems. ⁹ All units meet or exceed ASHRAE 90.1 standards. ¹⁰ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards. : PTH m — r roduCT PeCifiCATions odels everse yCle...
  • Page 6 • OAT— Outdoor Air Temperature (Wireless-ready models only) of a sealed system failure. Unit must not operate compressor • Orange—Miscellaneous thermistor or analog device (optional) and electric heaters simultaneously. vAPorATor ondenser omPressor Direct drive with a permanent, split-capacitor, two-speed indoor The compressor must be hermetically sealed, internally isolated, motor. Condensate must be directed onto the back and sides of rotary-type and permanently mounted on rubber isolators. No the coil to aid in evaporation and removal. removal or adjustment of compressor hold-down bolts is to be required during installation. isCHArge Must be a sloped surface so that obstructions cannot be placed ArrAnTy on the unit. Discharge conditioned air can be directed into the The warranty is for Full One Year on the entire unit; Full 2nd through room at an angle of 16 or 56 degrees from the vertical position. 5th Year on the entire sealed refrigerant system components; The discharge grille must be of polycarbonate material to resist Limited Second through Fifth Year on functional parts only. bending, cracking, rusting and corrosion. www.amana-ptac.com SS-DPTAC...
  • Page 7 Must be installed to prevent tampering of the unit controls. A manufacturer-approved manual, auto changeover or Unit room cabinet must also be secured to the chassis with programmable traditionally wired thermostat must be field supplied screws. UL-approved for institutional use only. installed to provide full remote operation of the chassis. A Remote Escutcheon Kit must be used to indicate remote isConneCT WiTCH Power disconnect switch must be installed in subbase for operation. use as a physical disconnect, where required by local codes. SS-DPTAC www.amana-ptac.com...
  • Page 8: Monthly Maintenance

    Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P. All rights reserved. Our continuing commit- ment to quality products may mean a change in specifications without notice. © 2013 • Goodman Company, L.P. • Houston, Texas • Printed in the USA.