Annual Inspection
It is suggested that your unit be inspected by your dealer or
servicer once a year. It is advisable to have the outer case
removed and the unit thoroughly cleaned.
Note: The life of your unit may be greatly reduced if you live
in a salt air or other corrosive type environment. Under these
conditions, the unit should be removed from its case and
completely cleaned at least once a year. At that time any
scratches or blisters on the painted surfaces should be
sanded and repainted. Placing an algaecide tablet in the
outdoor side of the unit's basepan is suggested in humid
areas where algae formation is common. We recommend the
following algaecide cleaners: PanGuard
Technologies, Inc. and CDC Anti-Clog
Front Grille and Filter Removal
The front contains a removable grille that provides easy
access to the air filter. To clean the filter, grasp filter handle
and slide filter out of unit.
1. Remove 2 side Phillips screws attaching front to case.
2. Remove inlet panel by pulling and lifting out bottom.
Reinstall air filter and grille by reversing removal procedure.
Front Grille and Cabinet Cleaning
Grille and cabinet may be cleaned with warm water and mild
soap or detergent. Cleaning and polishing compounds are not
recommended, as they may damage plastic surfaces.
Air Filter Cleaning
A dirty air filter reduces operating efficiency of unit. Filter
should be inspected at least once every week during opera-
tion. Clean filter with vacuum cleaner or wash in warm water
and mild detergent. Filter should be thoroughly dried before
replacing in unit. Do not operate unit without filter in place.
Fan Motor Care
The fan motor is permanently lubricated for long life. There is
no need to oil the motor.
Slide-out Chassis Removal from Outer Case
®
by Control Released
®
by Virginia KMP.
NOTE: Basepan clip is shipped in plastic bag with mounting
screw and condensate drain cup. Install clip after reinserting
chassis into outer case to prevent accidental chassis removal.
4
See Figure H.
3. Remove Phillips screw on bottom right of inlet panel area
and remove front panel.
Figure H
4. If the unit has a screw holding the basepan clip to the
chassis, remove the screw.
CAUTION
To reduce the risk of personal injury be
sure to have sufficient help when moving
your unit. A room air conditioner can
weigh between 70 and 240 pounds.
5. Using basepan handle, pull chassis straight out, slowly
and evenly, until approximately 9-12 inches extends
from outer case. Use both hands to grasp basepan and
pull remaining chassis from outer case.
Basepan