Whirlpool W10477534B Installation Instructions Manual page 17

30" (76.2 cm) freestanding gas ranges
Table of Contents

Advertisement

Available languages

Available languages

4. Remove the cap from the gas pressure regulator using a
flat-blade screwdriver.
NOTE: Make sure sealing washer remains in the same
position.
5. To convert to Natural gas, unscrew the plastic adjustment
screw by hand, turn it over, and screw it in again.
Inlet pressure
to LP gas
180º
A. Cap
B. Sealing washer
C. Adjustment screw
6. Reinstall the cap.
To Convert Surface Burners
1. Remove burner grate, burner caps and burners.
A. Burner cap
B. Burner
2. Locate the Natural gas orifice spuds for top burners in the
package containing literature included with the range. Three
Natural gas spuds are stamped "149" and one "165."
3. Remove the LP gas orifice spuds using a 7 mm combination
wrench.
A
A. Cap
Inlet pressure
to Natural gas
A
B
C
A
B
4. Install the Natural gas orifice spuds using a 7 mm
combination wrench.
A. Spud
B. Holder
NOTE: Depending on model, the range cooktop may be
equipped with 4 standard burners or 3 standard burners and
1 super burner. Spud size and location remain the same.
For models with 4 standard burners:
Std Burner 149
Std Burner 149
For models with 3 standard burners and 1 super burner:
Std Burner 149
Super Burner 165
5. Place LP gas orifice spuds in the parts bag for future use and
keep with the package containing literature.
6. Reinstall burners, burner caps and burner grates.
A
B
Std Burner 149
Std Burner 149
Std Burner 149
Std Burner 149
17