Installer options (ISU)
7
ISU
Function
5080
Return Air Sensor Type
5090
Terminals Wired to Discharge Air Sensor
5100
Discharge Air Sensor Type
5110
A-Coil Low Temperature Cutoff
6000
Select the Dry Contacts in the System
6010
Terminals Wired to Remote Setback Dry Contact
6020
Remote Setback Dry Contact Setup
6030
Remote Setback Time Delay
6040
Remote Setback - Standby Cool Setpoint
6040
Remote Setback - Standby Heat Setpoint
6050
Terminals Wired to Full Drain Pan Alert
Dry Contact
6060
Full Drain Pan Alert Dry Contact Setup
6070
Terminals Wired to Dirty Filter Alert Dry Contact
6080
Dirty Filter Alert Dry Contact Setup
6090
Terminals Wired to Water Leak Alert Dry Contact
6100
Water Leak Alert Dry Contact Setup
6110
Terminals Wired to System Shutdown
Alert Dry Contact
6120
System Shutdown Alert Dry Contact Setup
6130
Terminals Wired to Service Needed
Alert Dry Contact
6140
Service Needed Alert Dry Contact Setup
6150
Terminals Wired to Fan Failure Alert Dry Contact
6160
Fan Failure Alert Dry Contact Setup
6170
Terminals Wired to Custom Alert Dry Contact
6180
Custom Alert Dry Contact Setup
6190, 6200 Custom Alert Name and Message
7000
Filter Type
7020
Number of Air Filters
7110
Air Filter Replacement Reminder
7110
Air Filter 2 Replacement Reminder
7120
EAC Cell Cleaning Reminder
7120
EAC Pre-Filter Cleaning Reminder
7120
EAC Post-Filter Replacement Reminder
8000
Humidifier Type
8010
Indoor Sensor Used for Humidification Control
8030
Terminals Wired to the Humidifier
8050
Humidification - Window Protection
8060
System Modes Allowing Humidification
8070
Humidification Control
8080
Humidifier Lockout
8100
Clean Tank / Water Filter Replacement Reminder
8100
Humidifier Pad Replacement Reminder
9000
Dehumidification Equipment
9010
Indoor Sensor Used for Dehumidification Control
9020
Humidity Sensor Displayed on the Home Screen
9040
Terminals Wired to Dehumidification Equipment
9050
A/C with Low Speed Fan Setup
9050
Hot Gas Bypass Setup
9070
Dehumidification - Overcooling Limit
9080
Dehumidification Control
9090
Dehumidification Minimum On Time
9100
High Humidity Comfort Reset Setting
9110
Dehumidification High Limit Range Stop
69-2490_B.indd 9
THX9321/9421 Prestige
Thermostat functions
marked in gray below
ISU
Function
B
9120
System Modes Allowing Dehumidification
B
9130
Dehumidifier Fan Control
B
9140
Dehumidifier Lockout
B
9180
Dehumidification Away Mode
B
9190
Dehumidification Away Mode - Fan Control
C
9200
Dehumidification Away Mode -
C
Low Limit Temperature
C
9200
Dehumidification Away Mode -
C
Temperature Setting
C
9200
Dehumidification Away Mode -
Dehumidification Setting
B
9210
Dehumidifier Filter Replacement Reminder
B
10000
Ventilation Type
B
10020
Terminals Wired to Ventilator/Fresh Air Damper
B
10050
Ventilation Control Method
B
10060
Ventilation Fan Control
B
10090
Number of Bedrooms
10090
Size of House
C
10100
Ventilation Level (CFM)
C
10120
Ventilation Percent On Time
10130
Ventilation Low Temperature Lockout
B
10130
Ventilation High Temperature Lockout
B
10130
Ventilation High Dewpoint Lockout
C
10140
Lockout Ventilation on Hum/Dehum Calls
C
10160
Ventilate on High Indoor Humidity
B
10170
Ventilator Core Cleaning Reminder
B
10170
Ventilator Filter Cleaning Reminder
B
11000
Number of UV Devices
B
11050
UV Bulb Replacement Reminder
B
11050
UV Bulb 2 Replacement Reminder
B
12000
Installer Custom Reminders
B
13000
Heat Delta T Diagnostics
B
13010
Cool Delta T Diagnostics
B
13015
Set Advanced Delta T Diagnostic Options
B
13020
Allow Delta T Diagnostics During Humidification
B
13030
Allow Delta T Diagnostics During
B
Dehumidification
B
13040
Allow Delta T Diagnostics During Ventilation
B
13050-13080 Allow Heat Delta T Diagnostics:
B
Temp & Humidity
B
13090-13120 Allow Backup Heat Delta T Diagnostics:
B
Temp & Humidity
B
13130-13160 Allow Cool Delta T Diagnostics:
B
Temp & Humidity
B
13170
Defrost Cycle
B
13180
Delta T Fault Sensitivity
B
13190
Display Delta T Alerts to Homeowner
B
14000
Clock Format
B
14010
Daylight Saving Time
C
14020
Indoor Temperature Display Offset
R
14020
Indoor Humidity Display Offset
C
15000-15020 Dealer name, phone, email, website, message
C
C
C
9
IAQ and RF EIM
®
require an EIM (see page 3).
B
B
B
B
B
B
B
B
B
B
B
B
B
R
R
R
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
69-2490—03