At*Edfmtp Set Page Match Parameters; At*Edmin Enter And Display Microburst Mins - Sony Ericsson CM52 User Manual

Software user’s guide and at command manual
Hide thumbs Also See for CM52:
Table of Contents

Advertisement

5.2.4
AT*EDFMTP
Description
Sets the Configuration Packet
page match parameters,
duplicate page timer, and
Configuration Packet message
timer.
Displays the Configuration
Packet page match
parameters.
This command sets the office code prefix identifying Configuration Packet pages that are sent to this module,
the duplicate page filter timeout, and the Configuration Packet message timeout. The duplicate page filter
prevents the module from recognizing multiple pages (normally two) as separate events. The message
timeout indicates how long the module waits for receipt of all portions of a Configuration Packet. When the
timer expires, it indicates that the Configuration Packet sequence has not completed, and all page data is
discarded.
Parameter
<nx>
<dup_timeout>
<message_timeout>
The AT*EDFMTP command will return ERROR if the feature required for this function is not enabled. Feature
required for this command:
Aeris Microburst
o
5.2.5
AT*EDMIN
Description
Sets the MicroBurst MIN.
Displays the MicroBurst MIN's.
This command programs the additional MicroBurst MINs that the module must decode.
The primary MIN must be programmed before any other MINs are programmed, because the odd/even nature
of MINs 1-9 must be the same as the odd/even nature of the primary MIN. An error is indicated under the
following conditions:
An attempt is made to program MINs 1-9 if the primary MIN is not programmed.
If the MINs in any of the slots 1-9 are programmed, and an attempt is made to change the odd/even
status of the primary MIN.
If the primary MIN entered does not match, digit-for-digit, the MIN string stored in NAM2. This string
can be viewed using the AT*ERNAM command described in Section 4.3.2.
Entering a W (case insensitive) in any digit position within the 10-digit field for any of the MINs in slots 1-9
specifies a wildcard digit. Any incoming digit will match a wildcard digit except for a wildcard in the low-order
digit; in this case, the incoming digit must obey the odd/even rule with respect to the primary MIN in order for a
match to be detected.
Each new MIN entry is checked against all existing entries to ensure that no entry becomes ineffective due to
a range overlap. A new entry is not allowed under the following conditions:
Set Page Match Parameters
Syntax
AT*EDFMTP=<nx>,<timeout>,
<fmpt_timeout>
AT*EDFMTP?
Description
Special office code digits. Default is 99.
Timer to filter duplicate pages. Default is 15 seconds.
Timer to detect incomplete Configuration Packet page sequence. Default
is 30 seconds.
Enter and Display MicroBurst MINs
Syntax
AT*EDMIN=<slot>,
<mbmin>,
<act>,<ctrl><CR>
AT*EDMIN?<CR>
Confidential
USERS MANUAL
Document number
1/198 17-4/FCP 101 3045 Uen
Possible responses
OK
ERROR
*EDFMTP: <nx>, <dup_timeout>,
<message_timeout>
Possible responses
OK
*EDMIN: <slot>,<mbmin>, <act>, <ctrl>
125(158)
Revision
D

Advertisement

Table of Contents
loading

Table of Contents