Service Details - Ariston CX67SP6 X NG Operating, Care And Installation Instructions Manual

Hide thumbs Also See for CX67SP6 X NG:
Table of Contents

Advertisement

Service Details

To check or replace the ignition module
Electrical componentry and the electronic ignition pack are
primarily located at the rear of the Upright Cooker. Removal
of the back panel is straightforward.
IMPORTANT: First ensure that gas and electrical power
are disconnected before performing any service to this
appliance.
Using a Philips Head screwdriver remove the eight screws
on the perimeter of the rear panel.
Then remove the rear panel. Replacement is a reversal of
the above procedure.
Care must be taken to ensure that no damage occurs to
the spark ignition leads or the igniters.
Assembly is a reversal of the above procedure.
Service schedule
To keep your cooker running smoothly, we recommend that
you have your cooker serviced every 5 years by an author-
ised service agent.
Never use unauthorised technicians and never accept re-
placement parts which are not original.
ARISTON
PRIORITY SERVICE
If you are not completely satisfi ed
with your appliance or require
service call:
Australia
Phone: 1300 815 589
New Zealand
Phone: (09) 306 1020
AUSTRALIA
ARISIT PTY LIMITED
40-44 Mark Anthony Drive, Dandenong South,
VIC 3175, Australia
Fax: Service & Sales (03) 9768 0838
Email: consumer.care@arisit.com
cx67sp6_nz_0608
To check or replace the gas controls and gas
manifold
Removal of the gas manifold is initially accomplished by
removing the control knobs, the trivets, the burner caps and
burner head assemblies and skirts.
IMPORTANT: First ensure that gas and electrical power
are disconnected before performing any service to this
appliance.
Using a Philips Head screwdriver remove the control panel
securing screws and then remove the control panel. Care
must be taken to ensure that no damage occurs to the
spark ignition leads or the igniters.
Disconnect all ancillary gas piping.
Remove the two screws on each side of the control panel
that locates the gas manifold to the side panels. The gas
manifold may then be extracted.
Replacement is a reversal of the above procedure.
ALWAYS PERFORM A LEAK CHECK AFTER PERFORM-
ING ANY SERVICE ON THE GAS COMPONENTS OF THIS
COOKER. Correct procedure is described in the post-in-
stallation checks (page 5)
Service and spare parts are available on the numbers below.
Please have the following information handy:
The appliance model (Mod.).
The serial number (S/N).
This information can be found on the data plate located on
the appliance and/or on the packaging.
GENUINE ACCESSORIES
& SPARE PARTS
A wide range of genuine
accessories are available for
your appliance call:
Australia
Phone: 03 9768 0888
New Zealand
Phone: (09) 306 1020
NEW ZEALAND
ARISIT PTY LIMITED
PO Box 68-140 Newton, Auckland
1145, New Zealand
Fax: (09) 302 0077 -
Email: sales@aristonappliances.co.nz
12

Advertisement

Table of Contents
loading