Wiring Diagrams - Aiphone RY-18L Instructions

Form c relay for 12-18v dc intercom systems with door release

Advertisement

WIRING DIAGRAMS:

JF/JK OPEN VOICE COLOR VIDEO SYSTEM:
A1
Door
A2
ELECTRIC STRIKE
WIRING METHOD:
Use Normally Open
contact for electric strike
contact for magnetic lock
SPECIFICATIONS:
Power Source:
Mounting:
Terminations:
Relay Input:
Relay Output:
N/O Output rating:
N/C Ouptut rating:
Wiring:
Dimensions (HxWxD): 1-3/4" x 7/8" x 7/16", with wires extending approx. 7-1/2"
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
LOCK
.
POWER
+ -
Brn
COM
Org
Yel
Use Normally Closed
Supplied by master station
No mounting required
Color-coded prewired pigtails
12-18V DC, Red, Gray wires, 22AWG
Brown, Red, Orange wires, 18AWG
5A at 30V DC
10A at 125V AC
3A at 250V AC
3A at 30V DC or 125V AC
2 conductors from monitor's door release contacts to RY-18L.
2 conductors from RY-18L to strike, with power for strike wired in series.
Toll Free Technical Support:
E-mail tech-serv@aiphone.com
JK-1MD/MED
JF-2MED
A1
A2
B1
B2
S
S
PS-1820UL
DC 18V
+
+
-
-
RELEASE
Gry
(L)BRN
Red
(L)RED
N/O
N/C
MAGNETIC LOCK
WIRING METHOD:
LOCK
POWER
+ -
1-800-692-0200
NOTE:
Release contacts on the JF-2MED are from
4-pin connector included with unit.
Connect Red & Brown wires as shown.
Orange & Yellow wires are not used.
Release contacts on the JK-1MD/MED
are L/L terminals.
Add
JK-1MD/MED
jumper
wire from
JF-2MED
BRN to +
PS-1820UL
+
-
.
Gry
Red
Brn
COM
Org
N/O
Yel
N/C
NOTE:
Only wiring pertaining to connection of door
release relay is shown here.
For complete system information, please
consult the main system installation manual.
A1
A2
B1
B2
S
S
DC 18V
+
Add
-
jumper
wire from
BRN to +
RELEASE
(L)BRN
(L)RED
RY-18L Instr.
0310JD

Advertisement

loading