Chapter 8
Table 8-1. HP E1328A DAC Error Messages
No.
Title
-330
Self-Test Failure
-240
Hardware Failure
-221
Jumper Settings
2801
Channel 1 current
checksum error
2802
Channel 2 current
checksum error
2803
Channel 3 current
checksum error
2804
Channel 4 current
checksum error
2805
Channel 1 voltage
checksum error
2806
Channel 2 voltage
checksum error
2807
Channel 3 voltage
checksum error
2808
Channel 4 voltage
checksum error
Table 8-2. HP E1328A Tests/Checks
Test/Check
Reference
Designator
Heat Damage
- - - - - - - - - -
Switch Setting
SW1
A1 PCA
F1, F2
J101 - J402
P1
TB1 - TB4
Checking Heat Damage
Potential Cause(s)
Module malfunction
Module malfunction
Channel's V/I jumper in incorrect position
Channel 1 stored adjustment constant
(current) is corrupted
Channel 2 stored adjustment constant
(current) is corrupted
Channel 3 stored adjustment constant
(current) is corrupted
Channel 4 stored adjustment constant
(current) is corrupted
Channel 1 stored adjustment constant
(voltage) is corrupted
Channel 2 stored adjustment constant
(voltage) is corrupted
Channel 3 stored adjustment constant
(voltage) is corrupted
Channel 4 stored adjustment constant
(voltage) is corrupted
Check:
Discolored PC boards
Damaged insulation
Evidence of arcing
LADDR setting
Fuse continuity
Mating connector contacts
jumper in wrong position
Connector contacts
Service 51