Niles SI-1230 Installation & Operation Manual page 22

Systems integration amplifier
Table of Contents

Advertisement

Setting the Turn-On Mode Switch
The SI-1230 has three turn-on modes. Select the mode you want by sliding the
mode switch. See Installation Considerations on page 13 for more information
about each of the turn-on modes.
The Control Output
This terminal provides a 12V DC signal suit-
able for triggering Niles automated switchers,
some motorized screens, some electric curtain
controls, etc. This voltage is present only when
the amplifier is active or on. When the amplifier
turns off, the 12V signal is off.
STEP
1. Check the requirements of the
device you want to control.
2. Connect the 3.5mm Jack to the
control output maintaining proper
polarity (tip = +)
21
Slide the switch with either your fi ngernail or
a 1/8" slotted screwdriver blade.
DESCRIPTION
The control output has a maximum
current capability of 150 mA.
Niles makes an accessory cable
plug FG00724.
Using the
3.5 mm jack.