Climate Range; Ventilation - Miele GT 262 ES Operating And Installation Manual

Chest freezer with "stop frost" system
Table of Contents

Advertisement

Installation
The appliance should be installed on a
level and stable surface.
It should be situated far enough away
from a wall to ensure that the lid can be
opened and closed easily.
The appliance should be installed in a
dry well ventilated room.
The room temperature should not go
above or below the climate range for
which the appliance is designed. The
higher the ambient temperature of the
room the more energy the appliance re-
quires to operate. It should not be in-
stalled where it is exposed to direct
sunlight or directly adjacent to a heat-
producing appliance such as an oven
or a radiator.
To not install the appliance up against
other appliances or units. There must
be a minimum distance of 20 mm all
around the appliance to ensure suffi-
cient ventilation.
28
The appliance is designed for a particu-
lar climate range (ambient room tem-
perature), and should not be used out-
side this range. The climate range of
this appliance is stated on the data
plate outside the appliance.
SN, N
ST
T
The appliance will function perfectly
down to a temperature of +5 °C.
In order to ensure sufficient ventilation
– the gap between the bottom edge of
the freezer and the floor on which it
is standing must not be covered.
– there must be a minimum distance of
20 mm from the ventilation grille to
the wall to ensure sufficient ventila-
tion.
– the ventilation grille should be
dusted on a regular basis.
to + 32 °C
to + 38 °C
to + 43 °C