Electrical Connection U.k - Miele GT 262 ES Operating And Installation Manual

Chest freezer with "stop frost" system
Table of Contents

Advertisement

Electrical connection
The appliance is supplied with a mains
cable and moulded plug ready for con-
nection to an a.c. single phase 220 –
240 V 50 Hz supply. The fuse rating is
13 amps.
All electrical work should be carried
out by a suitably qualified and
competent person in accordance
with local and national safety regula-
tions.
Connection should be made via a
fused plug and suitable switched
socket which is easily accessible.
For extra safety it is advisable to in-
stall a residual current device (RCD)
with a trip current of 30 mA (in ac-
cordance with DIN VDE 0664, VDE
0100, Section 739).
Do not connect the appliance to the
mains electricity supply by an exten-
sion lead. Extension leads do not guar-
antee the required safety of the ap-
pliance (e.g. danger of overheating).
The appliance must not be connected
to an inverter and must not be used
with a plug adapter as these can cause
damage to the appliance's electronic
unit.
26
The wires in the mains lead are col-
oured in accordance with the following
code:
Green/yellow = earth
Blue
= neutral
Brown
= live
As the colours of the wires in the mains
lead of this appliance may not corre-
spond with the coloured markings ident-
ifying the terminals in your plug, pro-
ceed as follows:
The wire which is coloured green and
yellow must be connected to the termi-
nal in the plug which is marked with the
letter E or by the earth symbol (z) or
coloured green or green and yellow.
The wire which is coloured blue must
be connected to the terminal which is
marked with the letter N or coloured
black.
The wire which is coloured brown must
be connected to the terminal which is
marked with the letter L or coloured red.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents