^ Check that the temperature selector
is at a postion between "1" and "7".
^ Check the temperature display about
6 hours after switching on the appli-
ance. It will only display a tempera-
ture if the temperature inside the ap-
pliance is between 0 °C and 9 °C.
^ Has the contact switch got stuck?
^ Is the temperature selector at a set-
ting other than "0"? If it is then the
bulb may be defective and need re-
placing.
^ Disconnect the appliance from the
mains. Switch off at the wall and with-
draw the plug from the socket (pull
by the plug not the cable), or discon-
nect the mains fuse or remove the
screw-out fuse in countries where this
is applicable.
^ Reach into the back of the light cover,
press upwards at the side a then
pull the cover off b.
^ Replace the bulb with a new one.
Bulb specification:
220 – 240 V, max. 15 W, E 14 fitting.
^ Push the cover securely back into
position.
The drain hole has become blocked.
^ Clean the condensate channel and
drain hole.
If you still cannot remedy the fault
having followed these suggestions,
then contact the Miele Service De-
partment.
To prevent unecessary loss of tem-
perature it is advisable not to open
the door whilst waiting for the appli-
ance to be serviced.