Miele M 637 EC Operating Instructions Manual page 49

Table of Contents

Advertisement

All electrical work should be carried out
by a suitably qualified and competent
person in strict accordance with
national and local safety regulations.
The appliance is supplied with a cable
and moulded plug ready for connection
to a 230-240 V/50 Hz a.c. single phase
supply.
The voltage, rated load and fusing are
given on the data plate which is located
externally on the rear wall of the
appliance. Please ensure that these
match the household mains supply.
Connection should be made via a
suitable isolator, which should be easily
accessible after the appliance has
been installed.
For extra safety it is advisable to install
a residual current device with a trip
current of 30 mA.
The plug rating is 15 A.
Test marks
Electrically suppressed
according to
The wires in the mains lead of this
appliance are coloured in accordance
with the following code:
As the colours of the wires in the mains
lead of this appliance may not
correspond with the markings
identifying the terminals in your plug,
proceed as follows:
The wire coloured green and yellow
must be connected to the terminal in
the plug which is marked with the letter
E or by the earth symbol z or coloured
green or green and yellow.
The wire coloured blue must be
connected to the terminal marked with
the letter "N" or coloured black. The
wire coloured brown must be
connected to the terminal marked with
the letter "A" or coloured red.
Electrical safety
C-Tick Mark
AS/NZS 1044
49

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents