10) Fusible Link / Wire with fuse (00807)
Replacement Procedure:
Unplug the unit.
Remove the top panel (Two screws behind and slide back)
The fusible link is located on the heater housing as shown in the figure.
There is a small fuse inside the covering held by the clamp crewed on the housing.
Unfix the screw and replace the same and do the wiring as before / below.
Fix all the parts back by following the reverse procedure.
Wiring: Fusible Link
Remove blower fan
connector
Remove clamp screw
with Philip Screw driver
Fusible link
Remove heater connector
Testing Procedure:
Cold Test:
1) Check the continuity between the two terminals of the fusible link, if there is continuity
the fusible link is good.