DIP Switches

Some functions of the unit be changed by using
the DIP switches. These switches are located in
the Battery compartement of the unit.
ON
*...photoflash at the same position is used after photo with
insufficient light is attempted.
Lock
C/F
Buzzer
Backlight
Set Default
Ltd. Access
Ltd. Access
Laserflash
Photoflash
Auto/All
Time/Date
NTC/TC
TC-J/TC-K
Sets the unit into con-
tinuous measuring mode
Switches between
degrees Celsius and
Fahrenheit
Switches acoustic
signals On or Off
Switches the backlight of
the display On or Off
Sets the unit's values to
default, if On
If On, the function
buttons are blocked
If On, the laser will flash
when temperature val-
ues exceed alarm
If On, photoflash is
activated
Auto = automatic ...*
All = every photo is taken
with flash
Time or Date will be
displayed
Thermocouple settings -
refer to the
corresponding
chapter
576
27