TASK 25-62-03-450-803

4. Remote Switch Panel

SUBTASK 25-62-03-450-001
A.

Location

NOTE:
In most cases, panel space and wiring have been pre-provisioned by the aircraft
manufacturer for the G737 control panel (remote switch panel assembly); however, location
and installation requirements are defined for installations in aircraft not pre-provisioned for
this remote switch panel.
(1)
The Control Panel G737 (453-0161) must be mounted in the cockpit where the pilot can easily
reach the switch and see the status light.
(2)
The panel assembly requires a space approximately 5.74 x 2.24 in. (146 x 57 mm) on the
panel or console surface, with a depth of 3.00 in. (77 mm), excluding room for the harness
connection. See "Figure 16. Remote Switch Panel Assembly Outline and Dimensions".
5.74
(146)
5.365
(136.3)
ELT
ARM
ELT
ON
1.125 (28.6)
FRONT VIEW

Figure 16. Remote Switch Panel Assembly Outline and Dimensions

SUBTASK 25-62-03-450-002
B.

Installation

(1)
Provide an opening in the instrument panel or other mounting location which meets the
dimensional requirements shown in "Figure 16. Remote Switch Panel Assembly Outline and
Dimensions".
(2)
Mount Dzus rails on the sides of the opening, if necessary. See "Figure 16. Remote Switch
Panel Assembly Outline and Dimensions" for rail center line dimensions.
(3)
Install the remote switch panel assembly.
NOTE:
(4)
Apply a "For Aviation Emergency Use Only/Unauthorized Use Prohibited" placard as close to
the switch as practical, if required.
NOTE:
COBHAM AVIONICS WULFSBERG ELECTRONICS
ABBREVIATED COMPONENT MAINTENANCE MANUAL
B406-4 (453-5004)
4.969
0.185 (4.7)
(126.2
0.555 (14.1)
2.24
(57)
TOP VIEW
FASTENERS (4)
280-0010
(DZUS PA35-38X1426)
Step (3) may be completed after wiring is completed on the ELT end and the harness
plug has been plugged into the panel assembly, in accordance with the requirements
of SUBTASK 25-62-03-450-008, on page 70. If such is the case, perform a fit check
at this time.
This placard is recommended for installations on aircraft that are not pre-placarded
for remote ELT control. If desired, the placard (591-0428) may be ordered from
Wulfsberg Electronics Division.
+0.030
-0.000
0.69 (18) MAX.
)
+0.8/-0.0
3.000
±0.015
(76.2
)
±0.4
1.13 (29) MAX.
25-62-03
0.06 (2) MIN.
0.37 (9) MIN.
+0.030
2.094
-0.000
(53.2
+0.8/-0.0
BACK VIEW
453-0161
DIMENSIONS IN INCHES (MM)