Air-Conditioners For Building Application INDOOR UNIT PKFY-P·VBM-E / PKFY-P·VHM-E PCFY-P·VKM-E / PFFY-P·VKM-E PMFY-P·VBM-E OPERATION MANUAL FOR USER English For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
Contents 1. Safety Precautions ................2 7. Other Functions ................11 2. Parts Names ..................3 8. Function Selection ................12 3. Screen Confi guration ................6 9. Emergency operation for wireless remote-controller ...... 16 4. Setting the Day of the Week and Time ..........6 10.
2. Parts Names Wired Remote-Controller “Sensor” indication Day-of-Week Displayed when the remote controller Display Section sensor is used. Shows the current day of the week. For purposes of this explana- Time/Timer Display tion, all parts of the display are “Locked” indicator Shows the current time, unless the simple or Auto shown.
Page 5
2. Parts Names Wireless Remote-Controller Transmission area Transmission indicator Remote controller display Timer indicator * For explanation purposes, all of the items that appear in the display are shown. * All items are displayed when the Reset button is pressed. Operation areas ON/OFF button Set Temperature buttons...
3. Screen Confi guration <Screen Types> For details on setting the language for the remote controller display, refer Function Selection of remote controller Set Day/Time to section 8. Function Selection. The initial language setting is English. Function Selection of remote controller: Set the functions and ranges available to the remote controller (timer functions, operating restrictions, etc.)
Page 7
5. Operation 5.2. Mode select Note: The number of available fan speeds depends on the type of unit Press the operation mode ( ) button and select the op- connected. Note also that some units do not provide an “Auto” eration mode setting.
5. Operation <[Manual] To Change the Airfl ow’s Left/Right Direction> Note: * The louver button 7 cannot be used. Available directions depend on the type of unit connected. Note • Stop the unit operation, hold the lever of the louver, also that some units do not provide an “Auto”...
Page 9
6. Timer 6.1.2. Simple Timer <Setting the Weekly Timer> 5. Press the appropriate Set Time button 1 as necessary to set the de- You can set the simple timer in any of three ways. sired time (at 5). • Start time only: * As you hold the button down, the time fi...
Page 10
6. Timer 7. After completing steps 3 to 6 above, press the Filter button 4 to Example 2: Start the timer with OFF time set earlier than ON time lock in the value. ON Setting : 5 hours Note: OFF Setting: 2 hours Your new settings will be cancelled if you press the Mode (Return) button 2 before pressing the Filter button 4.
6. Timer <Checking the Current Auto Off Timer Setting> 6.2. For Wireless Remote-controller Timer Setting 1. Be sure that the “Auto Off” is visible on the screen (at 1). 2. Hold down the Timer Menu button 2 for 3 seconds so that “Monitor” is indicated on the screen (at 4).
7. Other Functions 7.2. Error Codes indication ON lamp (Blinking) Error Code Unit No. If you have entered contact number to be called in the event of a problem, the screen displays this number. (You can set this up under Function Selection of remote controller. For information, refer to section 8.) If the ON lamp and error code are both blinking: This means that the air conditioner is out of order and operation has been stopped (and cannot resume).
Page 13
8. Function Selection [Function selection fl owchart] Normal display (Display when the air conditioner is not running) Hold down the button and press the button for 2 seconds. Setting language (English) Press the operation mode button. Hold down the button and press the button for 2 seconds.
Page 14
8. Function Selection [Detailed setting] [4]–3. Mode selection setting (1) Remote controller main/sub setting [4]–1. CHANGE LANGUAGE setting ON/OFF] button D. • To switch the setting, press the [ The language that appears on the dot display can be selected. 1 Main: The controller will be the main controller.
Page 15
8. Function Selection [Dot display table] Selecting language English German Spanish Russian Italian Chinese French Japanese Waiting for start-up Operation mode Cool Heat Auto Auto(Cool) Auto(Heat) Ventilation Stand by (Hot adjust) Defrost Set temperature Fan speed Not use button Check (Error) Test run Self check Unit function selection...
9. Emergency Operation for Wireless Remote-controller When the remote-controller cannot be used When the batteries of the remote controller run out or the remote control- ler malfunctions, the emergency operation can be done using the emer- gency buttons. A DEFROST/STAND BY lamp B Operation lamp C Emergency operation switch (heating) D Emergency operation switch (cooling)
Page 17
10. Care and Cleaning PCFY-P·VKM-E PFFY-P·VKM-E 1 Open the intake grille. 2 Hold the knob on the fi lter then pull the fi lter up in the direction of an arrow. To replace the fi lter after cleaning, be sure to insert the fi...
11. Trouble Shooting Having trouble? Here is the solution. (Unit is operating normally.) Air conditioner does not heat or cool well. Clean the fi lter. (Airfl ow is reduced when the fi lter is dirty or clogged.) Check the temperature adjustment and adjust the set temperature. Make sure that there is plenty of space around the outdoor unit.
Page 19
11. Trouble Shooting Having trouble? Here is the solution. (Unit is operating normally.) Noise is louder than specifi cations. The indoor operation sound level is affected by the acoustics of the par- ticular room as shown in the following table and will be higher than the noise specifi...
12. Specifi cations PCFY-P·VKM-E Series Model P100 P125 Power source (Voltage<V>/Frequency) <Hz> ~/N 220-230-240/50, 220/60 Capacity (Cooling/Heating) <kW> 4.5/5.0 7.1/8.0 11.2/12.5 14.0/16.0 Dimension (Height) <mm> Dimension (Width) <mm> 1280 1600 Dimension (Depth) <mm> Net weight <kg> Fan Airfl ow rate (Low-Middle2-Middle1-High) <m /min>...