Download Print this page

Lennox Hearth Products WINSLOW PI40 Quick Start Manual page 4

Pellet insert

Advertisement

CLEANING AND MAINTENANCE SCHEDULE (CONTINUED)
In addition to the regular maintenance procedures described below, the "Installation and Operation Manual" out-
lines yearly service that should be performed by a qualified technician.
Burn Pot
The burn pot should be checked
for clinkers prior to operating
the fireplace insert. Any non-
combustible material blocking the
burn pot should be emptied prior
to ignition.
1-7 Days*
Ash Cavity
The ash drawer serves as a
receptacle to hold ash that has
accumulated in the firebox. Refer
to the Installation and Operation
Manual for proper ash disposal.
2 Days - 2 Weeks*
*Burning fuel with a high ash content or an improperly adjusted damper may require more frequent cleaning and fireplace insert maintenance.
IMPORTANT NOTE:
BURNING POOR QUALITY FUEL WILL SIGNIFICANTLY INCREASE THE FREQUENCY OF REQUIRED CLEANING.
FAILURE TO PROPERLY CLEAN AND MAINTAIN YOUR FIREPLACE INSERT AS INDICATED IN THE INSTALLATION
AND OPERATION MANUAL CAN RESULT IN AN FIREPLACE INSERT THAT IS UNSAFE TO OPERATE.
©Lennox Industries Inc. 2009
Visit us at www.Lennox.com, or contact us at 1-800-9-LENNOX.
P/N 506033-39 Rev. NC 10/2009
WARNING
Hot! Do not touch! The glass and surface of this appliance will
be hot during operation and will retain heat for a while after
shutting off the appliance. Severe burns may result.
Carefully supervise children in the same room as appliance.
Lennox pellet-burning appliances are designed for use as
supplemental heaters. They are not intended for continuous use
as primary heat sources.
Heat Exchanger
Keeping the heat exchanger
tubes clean will maximize
the heating efficiency of your
fireplace insert. When the insert
is cold, pull the tube scraper rod
back and forth to release any ash
build-up inside the firebox.
2 Days - 2 Weeks*
Additional Yearly
Maintenance*
Clean Proof of Fire Switch
Clean Ash Clean-Out Ports
Clean Exhaust Passages/Vent
Pipe and Creosote Removal
• Clean the Combustion and
Convection Blowers
Check Glass Door Seal
Cleaning Rear Fireplace Insert
Compartment

Advertisement