Page 1
Product Manual Momentus 5400.2 ® ST9120821A ST9100824A ST98823A ST96812A ST94813A ST93811A 100367120 Rev. B August 2007...
Page 2
SeaBOARD, SeaFONE, SeaTDD, and SeaTools are either trademarks or registered trade- marks of Seagate Technology LLC or one of its affiliated companies in the United States and/ or other countries. All other trademarks or registered trademarks are the property of their respective owners.
Introduction ® This manual describes the functional, mechanical and interface specifications for the following Seagate ® Momentus 5400.2 drives: • ST9120821A • ST9100824A • ST98823A • ST96812A • ST94813A • ST93811A These drives provide the following key features: • 5,400-RPM spindle speed and 8-Mbyte buffer combine for superior performance.
When addressing these drives in LBA mode, all blocks (sectors) are consecutively numbered from 0 to n–1, where n is the number of guaranteed sectors as defined above. Physical organization Model Read/write heads Number of discs ST9120821A ST9100824A ST98823A ST96812A ST94813A ST93811A Momentus 5400.2 PATA Product Manual, Rev. B...
However, due to the manner in which these drives are formatted, benchmark tests that include command overhead or measure logical seeks may produce results that vary from these specifications. Time to ready ° Time to ready Typical Max @ 25 Power-on to Ready (sec) Standby to Ready (sec) Momentus 5400.2 PATA Product Manual, Rev. B...
Idle, low power mode* 0.80 watts Standby 0.26 watts Sleep 0.26 watts *During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and power to operational levels. Momentus 5400.2 PATA Product Manual, Rev. B...
10 MHz. Note. Equivalent resistance is calculated by dividing the nominal voltage by the typical RMS read/write current. 2.9.3 Voltage tolerance Voltage tolerance (including noise): 5V ± 5% Momentus 5400.2 PATA Product Manual, Rev. B...
If the standby timer reaches zero before any drive activity is required, the drive makes a transition to Standby mode. In both Idle and Standby mode, the drive accepts all commands and returns to Active mode when disc access is necessary. Momentus 5400.2 PATA Product Manual, Rev. B...
Wet bulb temperature Operating 30°C (86°F max) Nonoperating 40°C (104°F max) 2.10.4 Altitude Operating –304.8 m to 3,048 m (–1,000 ft to 10,000 ft) Nonoperating –304.8 m to 12,192 m (–1,000 ft to 40,000 ft) Momentus 5400.2 PATA Product Manual, Rev. B...
The following table lists the maximum nonoperating vibration that the drive may experience without incurring physical damage or degradation in performance when subsequently put into operation. 5–500 Hz 5.0 Gs (0 to peak). Max displacement may apply below 22 Hz. Momentus 5400.2 PATA Product Manual, Rev. B...
A - 1) No upset or degradation in performance beyond manufacturer’s specified limits. 2) No data loss. B - 1) Unit self recovers without user intervention. 2) No data loss. C - 1) Upset OK provided that unit will function after user intervention. Momentus 5400.2 PATA Product Manual, Rev. B...
Information Technology Equipment (ITE). Emission levels are defined by EN 55022, Class B and the immunity levels are defined by EN 55024. Seagate uses an independent laboratory to confirm compliance with the EC directives specified in the previous paragraph. Drives are tested in representative end-user systems. Although CE-marked Seagate drives comply with the directives when used in the test systems, we cannot guarantee that all systems will comply with the directives.
As a subassembly, no Federal Communications Commission verification or certification of the device is required. Seagate Technology LLC has tested this device in enclosures as described above to ensure that the total assembly (enclosure, disc drive, motherboard, power supply, etc.) does comply with the limits for a Class B computing device, pursuant to Subpart J, Part 15 of the FCC rules.
The silver, copper, nickel and gold films used in Seagate products are especially sensitive to the presence of sulfide, chlo- ride, and nitrate contaminants. Sulfur is found to be the most damaging. In addition, electronic components should never be exposed to condensing water on the surface of the printed circuit board assembly (PCBA) or exposed to an ambient relative humidity greater than 95%.
• Do not remove the factory-installed labels from the drive or cover them with additional labels. Removal voids the warranty. Some factory-installed labels contain information needed to service the drive. Other labels are used to seal out dirt and contamination. Momentus 5400.2 PATA Product Manual, Rev. B...
CSEL, on the interface bus. Master and slave drives are determined by their physical position on the cable. To enable cable select, set a jumper as shown in Figure 3. Refer to your computer manual to determine whether your computer supports this option. Momentus 5400.2 PATA Product Manual, Rev. B...
0.148 ±.010 X 90 2 .152 .399 DETAIL A (PATA) 2.430 .039 B C D .016 2 .012 .370 .160 DETAIL A DETAIL A (SATA) Figure 4. Mounting dimensions—top, side and end view Momentus 5400.2 PATA Product Manual, Rev. B...
PIO data-transfer cycle timing mode 0200 Retired 0200 Words 54–58, 64–70 and 88 are valid 0007 Number of current logical cylinders xxxx Number of current logical heads xxxx Number of current logical sectors per logical track xxxx Momentus 5400.2 PATA Product Manual, Rev. B...
Page 32
Enhanced security erase time 0000 Advanced power management value 0040 Master password revision code FFFE Hardware reset value (see description following this table) xxxx Auto acoustic management setting xxxx 95–127 ATA-reserved 0000 Security status 0001 Momentus 5400.2 PATA Product Manual, Rev. B...
Page 33
Ultra DMA mode 3 is currently active. Ultra DMA mode 4 is currently active. Ultra DMA mode 5 is currently active. Word 93 1 = 80-conductor cable detected, CBLID above V 0 = 40-conductor cable detected, CBLID below V Momentus 5400.2 PATA Product Manual, Rev. B...
Disable write cache. Enable read look-ahead (read cache) feature (default). Report full capacity available Note. At power-on or after a hardware or software reset the default values of the features are as indicated above. Momentus 5400.2 PATA Product Manual, Rev. B...
Special training or tools may be needed to service some mobile computers. In some cases, opening the case may void your warranty. Consult your system documentation. Seagate recommends taking your system to an authorized service technician to replace your hard drive.
Page 36
System Compatibility Seagate Product Assurance has tested Momentus drives in the systems listed in Table 9. Testing included mul- tiple BIOS versions and operating systems. This testing was done to demonstrate compatibility with various hardware and software configurations. Hardware and software combinations, other than those tested, may also be compatible with this drive.
BIOS versions tested The following list indicates the types of BIOS Seagate tested during the compatibility testing process. The list highlights the major BIOS manufacturers. Individual systems contain variations of these BIOS versions and were tested with regard to their implementation in the individual systems.
Seagate Momentus drives with other ATA/ATAPI-6 compliant peripherals. Software utilities The following is a brief overview of a some of the Seagate utilities used during the Seagate competitive analy- sis process. The Seagate SeaTools application is an exclusive disc drive diagnostic software designed to troubleshoot most hard drive issues.
+1-405-324-4770. Seagate Service Centers Presales Support Our Presales Support staff can help you determine which Seagate products are best suited for your specific application or computer system, as well as drive availability and compatibility. Technical Support If you need help installing your drive, consult your system's documentation or contact the dealer's support ser- vices department for assistance specific to your system.
Page 40
Data Recovery Services Seagate offers data recovery services for all formats and all brands of storage media. Our Data Recovery Ser- vices labs are currently located in North America. To get a free quick quote or speak with a case management representative, call 1-800-475-0143.
Page 41
European support services For presales and technical support in Europe, dial the Seagate Service Center toll-free number for your spe- cific location. If your location is not listed here, dial our presales and technical support call center at +1-405- 324-4714 from 8:00 .
Page 42
Hours of operation are 8:30 to 5:30 Monday through Friday (Australian Western time). Hours of operation are 9:00 to 6:00 Monday through Saturday. Hours of operation are 9:30 to 6:30 Monday through Friday. Authorized Service Center Momentus 5400.2 PATA Product Manual, Rev. B...
Page 43
We are interested in your comments and suggestions regarding this publication. Please take a few minutes to participate in our survey at the following URL: http://survey.seagate.com/survey/techpubs.nsf Thank you for your time and comments. Momentus 5400.2 PATA Product Manual, Rev. B...
Page 47
33 temperature 11 temperature gradient 11 third party utilities 32 time to ready 7 timers 10 TMR 1 track density 6 track-to-track seek time 7 TUV North America 14 UL 1950 14 Momentus 5400.2 PATA Product Manual, Rev. B...
Need help?
Do you have a question about the Momentus 5400.2 and is the answer not in the manual?
Questions and answers