JUKI SC-921 Instruction Manual page 38

Hide thumbs Also See for SC-921:
Table of Contents

Advertisement

@ 7 Initial motion UP stop position move function (Function setting No. 90)
Effective/ineffective of automatic return to UP stop position immediately after turning ON the power can be set.
9 0
@8 Function added to the needle up / down compensating switch (Function setting No. 93)
One sttch operaton can be performed only when the needle up / down compensatng swtch s pressed at the tme
of upper stop mmedately after turnng ON the power swtch or upper stop mmedately after thread trmmng.
9 3
@9 Continuous stitching + one shot stitching nonstop function (Function setting No. 94)
Ths functon s used to proceed a step to the next one wthout stoppng the sewng machne at the end
of the step when performng sewng wth the contnuous sewng and one-shot sewng combned usng the
programming function of the operation panel IP.
9 4
#0 Setting of max. number of rotation of the sewing machine head (Function setting No. 96)
Ths functon can set the max. number of rotaton of the sewng machne head you desre to use.
Upper limit of the set value varies in accordance with the sewing machine head to be connected.
9 6
4
0
#1 Main shaft reference angle compensation (Function setting No. 120)
Man shaft reference angle s compensated
1
2
0
#2 UP position starting angle compensation (Function setting No. 121)
Angle to detect UP position starting is compensated.
1
2
1
#3 DOWN position starting angle compensation (Function setting No. 122)
Angle to detect DOWN position starting is compensated.
1
2
2
#4 Setting of energy saving function during standby (Function setting No. 124)
It s possble to reduce power consumpton whle the sewng machne s n standby state. It should be noted
that the startup of the sewng machne may delay for a moment f ths functon s set.
1
2
4
0 : Ineffectve
1
1 : Effectve
0 : Normal (Only needle up / down compensatng sttchng operaton)
0
1 : One sttch compensatng sttchng operaton (upper stop / upper stop)
s performed only when aforementoned changeover s made.
0 : Normal (Stop when a step has completed.)
0
1 : The sewng machne proceeds to next step wthout stoppng after a
step has completed.
150 to Max. [st/mn] <50 / st/mn>
0
0
Settng range
0
– 60 to 60˚ <1 / ˚>
Settng range
0
– 15 to 15˚ <1 / ˚>
Settng range
0
– 15 to 15˚ <1 / ˚>
0 : Energy-savng mode s neffectve.
0
1 : Energy-savng mode s effectve.
– 36 –

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents