PHYSICAL DATA AND SPECIFICATIONS
MODEL NUMBERS
RGLH- SERIES
Input–BTU/Hr [kW]
Heating Capacity BTU/Hr [kW]
High Altitude Input [kW]
High Altitude Output
Capacity [kW]
Heat Ext. Static Pressure [kPa]
Blower (D x W) [mm]
Motor H.P. [W]–Speeds [W]–
PSC Type
Motor Full Load Amps
Heating Speed
Cooling Speed
Cooling CFM @ .5" [kPa] E.S.P.
(Nominal) [L/s]
Rated E.S.P. (In. W.C.) [kPa]
Temperature Rise Range °F
[°C]
Max. Outlet Air Temp. °F
[°C]
Standard Filter [mm]
Approx. Shipping Weight (Lbs.)
[kg]
AFUE–Electric Ignition Models
California Seasonal Efficiency–
Electric Ignition No
Models
x
NOTES: All models are 115V, 60HZ, 1Ø. Gas connection size for all models is
In accordance with D.O.E. test procedures.
See Conversion Kit Index Form No. 92-21519-52 for U.S. models and Form No. 92-21519-53 for Canadian models for high altitude derate.
MODEL IDENTIFICATION—DOWNFLOW MODELS
R
G
L
Rheem
Gas
Downflow
Design
Furnace
Series
[ ] Designates Metric Conversions
05EAUER
07EAUER
05NAUER
07NAUER
50,000 [15]
75,000 [22]
41,000 [12]
60,000 [18]
45,000 [13]
67,500 [19.8]
36,500 [10.7]
53,500 [15.7]
.10 [.025]
.12 [.029]
11 x 6
11 x 6
[279 x 152]
[279 x 152]
1
/
-4-PSC
1
/
-4-PSC
2
2
[373]
[373]
6.8
7.1
MED-LOW
MED-HIGH
HIGH
HIGH
1200
1200
[566]
[566]
.50 [.12]
.50 [.12]
25-55
40-70
[13.9-30.6]
[22.2-38.9]
155
165
[68.3]
[73.9]
(1) 14 x 20
(2) 12 x 20
[356 x 508]
[305 x 508]
85
105
[38.6]
[47.6]
82.2%
80.5%
75.9/76.2
74.4/74.9
H
—
07E
Heating Input Designation
Electric
NO x
Ignition
Model
05E
05N
50,000 [15 kW]
07E
07N
75,000 [22 kW]
10E
10N
100,000 [29 kW]
12E
12N
125,000 [37 kW]
15E
15N
150,000 [44 kW]
07EAMGR
10EAMER
07NAMGR
10NAMER
75,000 [22]
100,000 [29.3]
60,500 [18]
80,000 [23]
67,500 [19.8]
90,000 [26.4]
54,000 [15.8]
72,000 [21.1]
.12 [.029]
.15 [.037]
11 x 6 = 10*AU
11 x 7
[279 x 152]
[279 x 178]
11 x 7 = 10*AM
[279 x 178
3
/
-4-PSC
1
/
-4-PSC
4
2
[559]
[373]
9.5
7.1
MED-LOW
MED-HIGH
MED-HIGH
HIGH
1600
1200
[755]
[566]
.50 [.12]
.50 [.12]
55-85 = 10*AU
25-55
[30.6-47.2]
[13.9-30.6]
45-75 = 10*AM
[25-41.7]
155
190
[68.3]
[87.8]
(2) 12 x 20
(2) 12 x 20
[305 x 508]
[305 x 508]
105
115
[47.6]
[52.2]
81.1%
80.2%
75.1/75.5
75.2/75.2
1
/
" N.P.T.
2
A
Variations
A = Std.
Designation
Input
Cabinet
U = 11 x 6
BTU/HR
[279 x 152 mm]
B = Wide
M = 11 x 7
Cabinet
[279 x 178 mm]
R = 11 x 10
[279 x 254 mm]
10EBRJR
12EARJR
10NBRJR
12NARJR
100,000 [29.3]
125,000 [36.6]
81,000 [24]
99,000 [29]
90,000 [26.4]
112,500 [33]
72,500 [21.2]
89,000 [26.1]
.15 [.037]
.20 [.05]
11 x 10
11 x 10
[279 x 254]
[279 x 254]
3
/
-4-PSC
3
/
-4-PSC
4
4
[559]
[559]
9.5
9.5
MED-LOW
MED-LOW
MED-HIGH
MED-HIGH
2000
2000
[944]
[944]
.50 [.12]
.50 [.12]
40-70
40-70
[22.2-38.9]
[22.2-38.9]
190
180
[87.8]
[82.2]
(2) 14 x 20
(2) 14 x 20
[356 x 508]
[356 x 508]
120
140
[54.4]
[63.5]
80%
80%
74.7/74.7
75.2/75.3
U
E
Blower
Heating & Cooling
Designation
S = 500-1200 CFM
[236-566 L/s]
E = 1100-1330 CFM
[519-628 L/s]
G = 1450-1750 CFM
[684-826 L/s]
J = 1800-2075 CFM
[850-979 L/s]
Rheem Manufacturing Company
15EARJR
15NARJR
150,000 [44]
120,000 [35]
135,000 [39.6]
107,500 [31.5]
.20 [.05]
11 x 10
[279 x 254]
3
/
-4-PSC
4
[559]
9.5
MED-LOW
MED-HIGH
2000
[944]
.50 [.12]
50-80
[27.8-44.4]
190
[87.8]
(2) 14 x 20
[356 x 508]
150
[68.0]
80%
76.0/75.9