NOTICE:    Do  not  
attempt  to  turn  any  
fitting  connected  
to  the  storage  tank  
union  hex  nuts  that  
are  tightened.    Doing  
so  will  damage  the  
storage  tank  and  void  
the  manufacturer's  
warranty.
Water  Supply  Connections  -­  Top  of  Storage  Tank
Refer  to  the  illustration  on  next  page  
for  suggested  typical  installation.  
The  installation  of  unions  or  flexible  
copper  connectors  is  recommended  
on  the  hot  and  cold  water  connections  
so  that  the  storage  tank  may  be  
easily  disconnected  for  servicing  if  
necessary.  The  HOT  and  COLD  water  
connections  are  clearly  marked  and  
shut-­off  valve  in  the  cold  water  line  
near  the  storage  tank.
The  cold  water  connection,  hot  water  
connection,  and  the  temperature  
and  pressure  relief  valve  may  be  
temporarily  disconnected  from  the  unit  
to  ease  installation  by  loosening  the  
union  hex  nuts  connecting  the  fittings  
to  the  storage  tank.    The  connection  of  
these  parts  to  the  unit  use  seal  rings  to  
form  a  water  tight  connection.    Re-­use  
Water  Connection  Ports  –  On  Sidewall  of  Unit
Two  water  connection  ports  are  
located  on  the  sidewall  of  the  tank.    
These  ports  have  1-­1/4"  female  NPT  
fittings.  (tapered  pipe  thread).
Teflon  pipe  tape  or  "dope"  are  
recommended  for  these  two  
connections.
Fittings  must  be  held  securely  (and  not  
To  Fill  the  Storage  tank
Make  certain  the  drain  valve  is  
completely  closed.  
Open  the  shut-­off  valve  in  the  cold  
water  supply  line.
Open  each  hot  water  faucet  slowly  to  
the  rubber  seal  rings  that  are  provided  
with  the  heater  when  re-­installing  
the  components.    Do  NOT  use  pipe  
sealant  on  this  joint.    Do  NOT  torque  
the  union  hex  nuts  to  over  35  ft-­lbs  
when  reinstalling  the  components.    
Failure  to  properly  reconnect  the  
fittings  provided  with  the  storage  tank  
will  void  the  manufacturer's  warranty.
SOLDER  WITH  CARE!!!    If  sweat  
connections  are  used,  do  NOT  apply  
heat  directly  to  any  component  
directly  connected  to  the  storage  
tank.    This  includes  the  cold  water  
connection,  hot  water  connection,  
temperature  and  pressure  relief  valve  
and  the  drain  valve.    Doing  so  will  
damage  the  storage  tank  beyond  repair  
and  void  the  manufacturer's  warranty.  
turn)  during  tightening  /  installation  /  
removal.    Failure  to  do  so  may  result  
in  catastrophic  damage  to  the  storage  
tank.    
It  is  recommended  that  a  threaded  
union  be  installed  near  the  tank.
Maximum  flow  rate  through  ports  is  
20  GPM.
allow  the  air  to  vent  from  the  storage  
tank    and  piping.  
A  steady  flow  of  water  from  the  hot  
water  faucet(s)  indicates  a  full  storage  
tank.