Installing  the  water  heater:
downward slope
94° Elbow
Fire
Stop
12" (min)
(30 cm)
Inspection
Access Panel #1
(optional)
CAUTION:  Condensate  
is  known  to  be  acidic;;  refer  
to  local,  state  (provincial)  
or  federal  codes  for  proper  
handling  and  discharge  
methods.
CAUTION:  Condensate  
must  drain  away  from  the  
water  heater  and  should  
not  be  allowed  to  enter  the  
water  heater.
WARNING:  Failure  to  
provide  a  vent  condensate  
drain  close  to  the  appliance  
could  allow  acidic  flue  gas  
condensate  to  enter  into  
appliance  flueways,  causing  
premature  failure  of  the  
water  heater.
WARNING:  If  the  
condensate  collector  is  not  
used,  the  drain  fitting  must  
be  capped  to  prevent  
exhaust  gases  and  
condensate  from  entering  
the  building.  The  cap  is  
supplied  on  the  water  
heater.
10
AP15317 (10_09) DV Gas Manual 10 30 09.indd 10
1/4" per foot
Wall Plates
Vent Pipe
Ceiling
Board
Inspection
Access
Panel #2
(optional)
Appliance  Vent   A dapter
Metal  Fab  Inc.,  standard  concentric  vent  pipe  
can  be  installed  into  the  water  heater  collar  
without  an  appliance  vent  adapter.  However,  
other  Rheem  approved  vent  manufacturer  pipe  
cannot  be  installed  without  a    UL  approved  
Category  III  Stainless  Steel  appliance  
concentric  vent  adapter.  
Draining  the  Condensate
Provision  should  be  made  to  collect  and  
dispose  of  condensate  from  venting  systems.
When  a  water  heater  is  vented  horizontally,  
the  vent  pipe  can  have  a  DOWNWARD  or  
UPWARD  slope  towards  the  termination.  If  an  
UPWARD  slope  is  used,  always  attach  a  drain  
hose  to  the  drain  fitting  and  plumb  the  hose  to  
a  sanitary  sewer  drain.  
See  Examples   A  and  B  on  pages  13  and  14  
for  DOWNWARD  and  UPWARD  slope  for  
horizontally  vented  water  heaters.  
Venting  Through  Closed  Spaces
Follow  local  codes  and  vent  manufacturer's  installation  instructions.
For  maintenance  and  inspection  purposes  two  (2)  inspection  access  
panels  large  enough  to  allow  access  for  venting  inspection  may  be  
required.  One  (1)  of  these  access  panels  should  be  close  to  where  the  
concentric  vent  pipe  enters  the  ceiling.  The  other  access  panel  should  
be  near  the  vent  termination.
Notice:  To  install  the  appliance  vent  adapter,  
please  follow  the  appliance  vent  adapter  
manufacturer's  instructions.
When  a  water  heater  is  vented  vertically,  an  
UPWARD  slope  must  always  be  used.    See  the  
diagram  on  page  14  showing  UPWARD  slope  
for  vertically  vented  water  heaters.
Always  attach  a  drain  hose  to  the  drain  fitting  
and  plumb  the  hose  to  a  sanitary  sewer  drain.
A  high  temperature  silicone  tubing  suitable  for  
use  with  acidic  condensate  and  appropriate  for  
the  temperature  range  should  be  used.
The  drain  tube  is  fashioned  into  a  "pigtail"  trap  
and  must  be  filled  with  water  to  prevent  flue  
gases  from  emitting  into  the  building  prior  to  
operating  the  appliance.  (see  diagram)
Condensate  Drain  Line  
(to  suitable  drain)
gasses  from  backing  into  building